Summary for Test 2023-09-24-32-1

Test performed: CTM 524-March 2013

Project Information

Project IdentifiersProject ID: 214336
DEA: 07302404
EFIS: 0713000488
DIST-CO-RTE-PM07-VEN-101-37/40
Award Date11/17/2020
Closeout Date09/24/2024
Work DescriptionPADRE JUAN REHAB
Location DescriptionVEN 101
QA Service Level1 (Verified on 02/26/2021)

Sample Information

Sample Taken Date09/24/2023 Sample Unique Key32
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/24/2023
Sample typeQuality Assurance A brief description of the sampleJPCP-RSC Beams
The quantity of what the sample constitutes10 CY From where was the sample collectedJob Site
First name of sampler or witnessed byFernando Last name of sampler or witnessed byCarranza
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameN/A Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberG3-22-PRS-299
The truck number from where the sample was collected The batch plant ticket number from where the sample was collected91
Concrete batch plant The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedConcrete from wheelbarrow Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-09-24-32
DIME Test ID: 2023-09-24-32-1
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 524-March 2013: Method of Test for Flexural Strength Of Rapid Strength Concrete
Test Release Date: 2023-11-16

Test Results


Number of specimens: 3
Does the testing machine measure load or stress on the beam specimen?: Load
Fracture initiates in the tension surface: Within the Middle Third of the Span Length
Fracture occurred at a capped section: No
Is a beam dimensional correction factor used?: Yes
Input Type: Measured
Tester's full name: Aleksey Souglobov
Date of test: 10/04/2023
Identification number: 23-1487
Width of specimen: 6 inch
Width of specimen 2: 6 inch
Width of specimen 3: 6 inch
Depth of specimen: 6 inch
Depth of specimen 2: 6 inch
Depth of specimen 3: 6 inch
Span length of specimen: 18 inch
Span length of specimen 2: 18 inch
Span length of specimen 3: 18 inch
Maximum load applied: 8680 lb
Maximum load applied 2: 9030 lb
Maximum load applied 3: 8870 lb
Correction Factor: 1
Correction Factor 2: 1
Correction Factor 3: 1
Curing history and apparent moisture condition of the specimen: 0
If specimen was capped, ground or if leather shims were used: 0
Defects in specimen, including numbers of beams discarded during test: 0
Age of specimen: 10 days
Age of specimen in hours: 0 hours
Modulus of rupture: 760 psi
Modulus of rupture 2: 790 psi
Modulus of rupture 3: 780 psi
Modulus of rupture average: 780 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/16/2023