Summary for Test 2023-11-06-53-5
Test performed: AASHTO T316-17Project Information
Project Identifiers | Project ID: 994328 DEA: 081H0604 EFIS: 0816000130 |
---|---|
DIST-CO-RTE-PM | 08-RIV-74-34.3/45.1 |
Award Date | 01/03/2023 |
Closeout Date | Not set |
Work Description | FIBER OPTIC CABLE SYSTEMS, RHMA, HMA, AND MINOR CONCRETE. |
Location Description | RIVERSIDE COUNTY IN AND NEAR HEMET FROM WINCHESTER ROAD TO FAIRVIEW AVENUE |
QA Service Level | 1 (Verified on 08/28/2023) |
Sample Information
Sample Taken Date | 11/06/2023 | Sample Unique Key | 53 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/13/2023 |
Sample type | Verification | A brief description of the sample | JMF Verification |
The quantity of what the sample constitutes | 1 Can | From where was the sample collected | Source |
First name of sampler or witnessed by | VICTOR | Last name of sampler or witnessed by | Capacete |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | All American Asphalt Perris | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
---|---|---|---|
Modified | Lot number | ||
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2023-11-06-53
DIME Test ID: 2023-11-06-53-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2023-11-16
Test Results
Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 11/15/2023
Time of test: 9:20 HH:MM
Test Temperature: 135 C
Speed: 20 rpm
Spindle size: 21 in
Torque: 54.6 %
Viscosity reading #1 (A) : 1.371 Pa-s
Viscosity reading #2 (B) : 1.361 Pa-s
Viscosity reading #3 (C): 1.358 Pa-s
Average viscosity: 1.363 Pa-s
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/16/2023 ✔