Summary for Test 2023-10-28-24-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993208 DEA: 034F38U4 EFIS: 0321000092 |
---|---|
DIST-CO-RTE-PM | 03-YUB-70-16.2/25.8 |
Award Date | 11/04/2021 |
Closeout Date | Not set |
Work Description | WIDEN SHOULDERS AND IMPROVE CLEAR RECOVERY ZONE. |
Location Description | YUBA COUNTY NEAR MARYSVILLE FROM 0.2 MILE NORTH OF LAURELLEN ROAD TO SOUTH HONCUT CREEK BRIDGE |
QA Service Level | 1 (Verified on 09/10/2021) |
Sample Information
Sample Taken Date | 10/28/2023 | Sample Unique Key | 24 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/28/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1/2" HMA-O |
The quantity of what the sample constitutes | 750 | From where was the sample collected | Source |
First name of sampler or witnessed by | Tim | Last name of sampler or witnessed by | NA |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 23-268 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Desilva Gates-Marysville | Transportation Laboratory (TL) Number | 849494 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Not Applicable |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 2 |
Sublot number | 13 | HMA Mix Number | MD 6730 |
Test Details
DIME Sample ID: 2023-10-28-24
DIME Test ID: 2023-10-28-24-2
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-11-14
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: KHUE YANG
Date of test: 11/14/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 4037.9 g
Mass of the specimen and specimen basket assembly prior to ignition: 5605.2 g
Mass of HMA Sample prior to ignition: 1567.3 g
Mass Loss: 90.3 g
Mass of aggregate remaining after ignition: 1477.0 g
Correction Factor (Percent by mass of HMA Specimen): 0.39 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.37 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/14/2023 ✔