Summary for Test 2023-10-14-9-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 994671
DEA: 010H8004
EFIS: 0118000110
DIST-CO-RTE-PM01-HUM-254-4.3/4.7
Award Date03/10/2023
Closeout DateNot set
Work DescriptionProject Name: Myers Flat Permanent Restoration
Location DescriptionBridge No. 04E0041
QA Service Level1 (Verified on 04/11/2023)

Sample Information

Sample Taken Date10/14/2023 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?No Date that the sample was received by the laboratory/organization performing the testing10/16/2023
Sample typeDepartment Acceptance A brief description of the sample6 4x8 Cylinders
The quantity of what the sample constitutes50 yards From where was the sample collectedJob Site
First name of sampler or witnessed bySami Last name of sampler or witnessed byDaouk
Title of samplerASR Telephone number of sampler
Laboratory sample identificationC0234 Linked DIME Sample ID
The fabricator/manufacturer/facility nameEureka Ready Mix Alton Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberE400F
The truck number from where the sample was collected84 The batch plant ticket number from where the sample was collected20590
Concrete batch plantEureka Ready Mix Alton The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedchute Where the material sample would have been placed if not sampledMiranda Soldier Pile Wall Whaler 1
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-10-14-9
DIME Test ID: 2023-10-14-9-2
Testing Lab: CT D01 - District 1 Materials Laboratory
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-11-11

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Calculated
Tester's full name: Jamie Kelley
Date of test: 11/11/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 66040 lb
Maximum load on cylinder 2: 63970 lb
Maximum load on cylinder 3: 67830 lb
Type of fracture pattern of cylinder 1: 5
Type of fracture pattern of cylinder 2: 5
Type of fracture pattern of cylinder 3: 5
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.6 in^2
Cross sectional area of cylinder 2: 12.6 in^2
Cross sectional area of cylinder 3: 12.6 in^2
Compressive strength (to nearest 10 psi): 5250 psi
General comments (publicly viewable) (Max 1000 characters): 28 Day Break 11/11/23

Test was verified on 11/11/2023