Summary for Test 2023-10-10-62-1

Test performed: CONCLP 4-16

Project Information

Project IdentifiersProject ID: 994596
DEA: 081M4904
EFIS: 0821000129
DIST-CO-RTE-PM08-SBD-10-6.9/20.0
Award Date05/16/2023
Closeout DateNot set
Work DescriptionPOLYESTER CONCRETE OVERLAY AND BRIDGE DECK TREATMENT.
Location DescriptionSAN BERNARDINO COUNTY AT VARIOUS LOCATIONS FROM 0.3 MILE WEST OF ARCHIBALD AVENUE OVERCROSSING TO RIVERSIDE AVENUE OVERCROSSING
QA Service Level1 (Verified on 07/10/2023)

Sample Information

Sample Taken Date10/10/2023 Sample Unique Key62
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/11/2023
Sample typeQuality Control A brief description of the sample2 pints 204,CHP,8020
The quantity of what the sample constitutes100 Totes From where was the sample collectedSource
First name of sampler or witnessed byGILBERTO Last name of sampler or witnessed byGONZALEZ
Title of samplerQuality Control Manager Telephone number of sampler17076245467
Laboratory sample identification000024KBP Linked DIME Sample ID000024KBP
The fabricator/manufacturer/facility nameKwik Bond Polymers, Benicia Transportation Laboratory (TL) NumberSacramento Caltrans lab
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeMethacrylate Mfg. Lot Number(s)2311791890
Batch number2311791890 Mix number2311791890

Test Details

DIME Sample ID: 2023-10-10-62
DIME Test ID: 2023-10-10-62-1
Testing Lab: CT HQ - Sacramento Concrete Testing Laboratory
Test Method: CONCLP 4-16: HMWM
Test Release Date: 2023-11-08

Test Results


Input Type: Calculated
Tester's full name: Rachael Chavez
Date of test: 11/02/2023
Viscosity (ASTM D 2196) Brookfield RVT with UL adapter, 50 RPM @ 77 deg F, 25 max cps @ 77 deg F: 20.5 cps
Specific gravity (ASTM D 1475) 0.90 min @ 77 deg F: 9
Volatile content (ASTM D 2369) 30% max: 8.75 %
Flash point (ASTM D 3828) more than 180 deg F: 190 F
PCC - SSD bond strength (CA Test 551) 500 psi minimum @ 24 hours: 832 psi
Tack free time, 400 minutes max: 350 minutes
General comments (publicly viewable) (Max 1000 characters): PCC-SSD Bond Strength CTM 551: 832 psi Tack free time ASTM C679: 350 mins. Both accepted based on vendor's results.

Test was verified on 11/8/2023