Summary for Test 2023-11-06-9-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 994326
DEA: 051C3604
EFIS: 0512000134
DIST-CO-RTE-PM05-SB-217-0.9/1.4
Award Date01/31/2023
Closeout DateNot set
Work DescriptionREPLACE BRIDGE.
Location DescriptionSANTA BARBARA COUNTY NEAR GOLETA FROM 0.2 MILE EAST OF GOLETA SLOUGH BRIDGE TO 0.4 MILE EAST OF SAN JOSE CREEK BRIDGE
QA Service Level1 (Verified on 10/17/2022)

Sample Information

Sample Taken Date11/06/2023 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing11/07/2023
Sample typeQuality Assurance A brief description of the sample#8 bar HRC 500-510 Couplers
The quantity of what the sample constitutes4 Couplers from 150 From where was the sample collectedFabricator
First name of sampler or witnessed byOsiell Last name of sampler or witnessed byRamirez
Title of samplerQuality Assurance Inspector Telephone number of sampler(916) 767-3535
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameIntegrity Rebar Placers Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormL123-099-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerVinton Steel
Coupler ManufacturerHRC Fountian Valley CA Intermediate Assembler or FabricatorIntegrity Rebar Placers
Rebar Size#8 Coupler ModelHRC 500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)5395277/5395277 Rebar Heat Number(s)2321443
Rebar Size 2 8 Coupler Unique IDTP-17-03

Test Details

DIME Sample ID: 2023-11-06-9
DIME Test ID: 2023-11-06-9-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2023-11-09

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 11/08/2023
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 8/25mm200.797549295559 Ok Necking rmacias

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 11/9/2023