Summary for Test 2017-03-06-7-6

Test performed: ASTM C191-13

Project Information

Project IdentifiersProject ID: 88888
DEA: SMTL-STOCK
EFIS: SMTL-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for SMTL stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date03/06/2017 Sample Unique Key7
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/06/2017
Sample typeProficiency A brief description of the sampleCCRL 079
The quantity of what the sample constitutes7800 Grams From where was the sample collectedOther
First name of sampler or witnessed byUnknown Last name of sampler or witnessed byUnknown
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationCM178079 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCCRL Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeCementitious BrandCCRL
MillCCRL Type of Cementitious MaterialBlended Cement

Test Details

DIME Sample ID: 2017-03-06-7
DIME Test ID: 2017-03-06-7-6
Testing Lab: CT HQ - Sacramento Cement Testing Laboratory
Test Method: ASTM C191-13: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle
Test Release Date: 2019-02-19

Test Results


Input Type: Calculated
Tester's full name: Stephen Donnelly
Date of test: 03/24/2017
Type of Water Used: Type IV grade reagent water
Initial time of setting: 138 min
Final time of setting: 230 min
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 2/12/2019