Summary for Test 2023-10-19-26-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993608 DEA: 081H8204 EFIS: 0817000138 |
---|---|
DIST-CO-RTE-PM | 08-SBD-15,138-R21.6,R14.8/R15.1 |
Award Date | 08/26/2022 |
Closeout Date | 03/28/2024 |
Work Description | SIGNAL AND LIGHTING SYSTEM, HMA, JPCP, AND ROADWAY EXCAVATION. |
Location Description | SAN BERNARDINO COUNTY IN PHELAN ON ROUTE 138 FROM 0.3 MILE WEST OF ROUTE 138/15 SEPARATION TO ROUTE 138/15 SEPARATION AND ON ROUTE 15 SOUTHBOUND EXIT RAMP AT ROUTE 138 |
QA Service Level | 1 (Verified on 11/16/2022) |
Sample Information
Sample Taken Date | 10/19/2023 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/24/2023 |
Sample type | Acceptance | A brief description of the sample | 3/4" HMA-A-SP R15 0.75% LAS |
The quantity of what the sample constitutes | 4 BOXES OF HMA | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | I NAJJAR | Last name of sampler or witnessed by | TE |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0538A-23 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Vulcan | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | |
Sublot number | HMA Mix Number | 224112A ORO SJR |
Test Details
DIME Sample ID: 2023-10-19-26
DIME Test ID: 2023-10-19-26-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-11-06
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 10/27/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2122.3 g
Mass Loss: 109.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.43 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 4.59 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/6/2023 ✔