Summary for Test 2023-10-27-48-3
Test performed: ASTM D5329-16Project Information
Project Identifiers | Project ID: 214336 DEA: 07302404 EFIS: 0713000488 |
---|---|
DIST-CO-RTE-PM | 07-VEN-101-37/40 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | PADRE JUAN REHAB |
Location Description | VEN 101 |
QA Service Level | 1 (Verified on 02/26/2021) |
Sample Information
Sample Taken Date | 10/27/2023 | Sample Unique Key | 48 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 11/01/2023 |
Sample type | Verification | A brief description of the sample | Asphalt Rubber Binder |
The quantity of what the sample constitutes | 1qt can | From where was the sample collected | Source |
First name of sampler or witnessed by | VICTOR | Last name of sampler or witnessed by | Pham |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | San Joaquin Refining Co Inc | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Rubber Binder | Asphalt modifier supplier | |
---|---|---|---|
Performance Grade | PG 64-16 | Lot number | |
Sublot number | Asphalt Rubber Binder Mix Number |
Test Details
DIME Sample ID: 2023-10-27-48
DIME Test ID: 2023-10-27-48-3
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: ASTM D5329-16: Standard Test Methods for Sealants and Fillers, Hot-Applied, for Joints and Cracks in Asphalt Pavements and Portland Cement Concrete Pavements (Asphalt Pavement)
Test Release Date: 2023-12-13
Test Results
Input Type: Measured
Tester's full name: Sm Ali
Date of test: 11/03/2023
Temperature: 25 C
Final Dial reading (F1): 76 mm
Ball Penetration (P1): 2 mm
Final Dial reading (F2): 76 mm
Ball Penetration (P2): 3 mm
Final Dial reading (F3): 75 mm
Ball Penetration (P3): 0 mm
Resilience 1: 26 %
Resilience 2: 27 %
Resilience 3: 25 %
Average Resilience: 26 %
Minutes Reaction: 45
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 12/13/2023 ✔