Summary for Test 2023-10-29-2-8
Test performed: AASHTO T96-02r10Project Information
Project Identifiers | Project ID: 993908 DEA: 11427104 EFIS: 1116000154 |
---|---|
DIST-CO-RTE-PM | 11-SD-8-3.0/8.3 |
Award Date | 04/12/2023 |
Closeout Date | 09/26/2024 |
Work Description | MODIFY SIGNAL & LIGHTING SYSTEMS & REPLACE MINOR CONCRETE CURB RAMP. |
Location Description | SAN DIEGO COUNTY IN SAN DIEGO AT VARIOUS LOCATIONS FROM MISSION CENTER ROAD OVERCROSSING TO COLLEGE AVENUE OVERCROSSING |
QA Service Level | 1 (Verified on 11/01/2022) |
Sample Information
Sample Taken Date | 10/29/2023 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/30/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA |
The quantity of what the sample constitutes | 12 boxes 3 bags | From where was the sample collected | Source |
First name of sampler or witnessed by | Jesse | Last name of sampler or witnessed by | Fuentes |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 10001-PSU | Linked DIME Sample ID | 2023-10-29-1 |
The fabricator/manufacturer/facility name | Vulcan Otay | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | 91-37-0035 |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-10-29-2
DIME Test ID: 2023-10-29-2-8
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T96-02r10: Standard Method of Test for Resistance to Degradation of Small-Size Coarse Aggregate by Abrasion and Impact in the Los Angeles Machine (Los Angeles Rattler)
Test Release Date: 2023-11-14
Test Results
Input Type: Measured
Tester's full name: Shawn Rivers
Date of test: 11/03/2023
Grading designation: B
Mass of sample (before test): 5000 grams
Mass of sample on No.12 sieve (after 100 revolutions): 4783 grams
Mass of sample on No.12 sieve (after 500 revolutions): 4554 grams
Percent loss after 100 revolutions: 4 %
Percent loss after 500 revolutions: 9 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/14/2023 ✔