Summary for Test 2023-10-17-50-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994561
DEA: 032G8604
EFIS: 0322000250
DIST-CO-RTE-PM03-PLA-80-R19.0/24.5
Award Date05/09/2023
Closeout DateNot set
Work DescriptionRHMA, COLD PLANE AC PVMT, & MODIFYING TRAFFIC MONITORING STATIONS.
Location DescriptionPLACER COUNTY 0.6 MILE EAST OF AUBURN FROM 0.1 MILE EAST OF RUSSELL ROAD OVERCROSSING TO 1.1 MILES EAST OF PLACER HILLS OVERCROSSING
QA Service Level1 (Verified on 05/15/2023)

Sample Information

Sample Taken Date10/17/2023 Sample Unique Key50
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/17/2023
Sample typeQuality Assurance A brief description of the sample1/2" RHMA-O
The quantity of what the sample constitutes750 From where was the sample collectedSource
First name of sampler or witnessed byDavid Last name of sampler or witnessed byDrane
Title of sampler Telephone number of sampler
Laboratory sample identification23-256 Linked DIME Sample ID
The fabricator/manufacturer/facility nameGeorge Reed - Rio Linda Transportation Laboratory (TL) Number764452
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeNot Applicable
HMA Grading1/2 inch Lot number
Sublot number HMA Mix NumberRL 12RHMAO 2023

Test Details

DIME Sample ID: 2023-10-17-50
DIME Test ID: 2023-10-17-50-1
Testing Lab: CT D03 - Olivehurst Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-11-01

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: KHUE YANG
Date of test: 10/31/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3970.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 6181.5 g
Mass of HMA Sample prior to ignition: 2211.5 g
Mass Loss: 181.7 g
Mass of aggregate remaining after ignition: 2029.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.34 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.88 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/1/2023