Summary for Test 2023-08-11-83-8
Test performed: AASHTO T209-12Project Information
Project Identifiers | Project ID: 994120 DEA: 040J6314 EFIS: 0421000252 |
---|---|
DIST-CO-RTE-PM | 04-SOL-12-21.2/22.6 |
Award Date | 09/16/2022 |
Closeout Date | Not set |
Work Description | ROADWAY RESURFACING, INSTALL DRAINAGE SYSTEM, MIDWEST GUARDRAIL SYSTEM |
Location Description | SOLANO COUNTY NEAR RIO VISTA FROM MCCLOSKY ROAD TO 0.1 MILE WEST OF AZEVEDO ROAD |
QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
Sample Taken Date | 08/11/2023 | Sample Unique Key | 83 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/28/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1/2-INCH HMA Type A |
The quantity of what the sample constitutes | LOT 1 SUBLOT 6 | From where was the sample collected | Source |
First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
Title of sampler | Telephone number of sampler | 7072999133 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Teichert Vernalis Drier Drum Plant | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 6 | HMA Mix Number | 30240442412V |
Test Details
DIME Sample ID: 2023-08-11-83
DIME Test ID: 2023-08-11-83-8
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-10-27
Test Results
Number of tests: 2
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 08/28/2023
Specific Gravity for Sample 1: 2.468
Specific Gravity for Sample 2: 2.468
Average Specific Gravity: 2.468
Theoretical maximum density at 25°C (77°F): 2.5 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Teichert Vernalis Drier Drum Plant
LOT 1 SUBLOT 6
Test PASSED
Test was verified on 10/27/2023 ✔