Summary for Test 2023-10-02-68-1
Test performed: AASHTO T48-18Project Information
Project Identifiers | Project ID: 44444 DEA: ASCP EFIS: ASCP |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for submitting Sample information for Asphalt Supplier Certification Program. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 10/02/2023 | Sample Unique Key | 68 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/02/2023 |
Sample type | Quality Control | A brief description of the sample | PG64-28M Modified Asphalt Binder |
The quantity of what the sample constitutes | 1 of 2 cans | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | John | Last name of sampler or witnessed by | Partenan |
Title of sampler | Sr Asphalt Technician | Telephone number of sampler | 6614327352 |
Laboratory sample identification | 6428231002 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | San Joaquin Refinery, Bakersfield, CA | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
---|---|---|---|
Modified | Yes | Lot number | 6428231002 |
Sublot number | Tank number | 5006 | |
Time of sample | 7:45am | HMA Supplier | |
Certified Asphalt Supplier | San Joaquin Refinery - Bakersfield CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2023-10-02-68
DIME Test ID: 2023-10-02-68-1
Testing Lab: San Joaquin Refinery - Bakersfield
Test Method: AASHTO T48-18: Standard Method of Test for Flash Point of Asphalt Binder by Cleveland Open Cup
Test Release Date: 2023-11-07
Test Results
Units of measurement for Observed Flash Point (C or F) and Ambient barometric pressure (kP or mmHg): Fahrenheit and mmHg
Input Type: Calculated
Tester's full name: Don Conner
Date of test: 10/02/2023
Observed Flash Point: 580 F
Ambient Barometric Pressure: 740 mmHg
Cleveland Open-Cup Flash Point in Fahrenheit: 580 F
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 11/7/2023 ✔