Summary for Test 2023-10-17-26-1
Test performed: ASTM C39-21Project Information
Project Identifiers | Project ID: 994330 DEA: 09366404 EFIS: 0916000006 |
---|---|
DIST-CO-RTE-PM | 09-MNO-395-58.2/60.4 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | HOT MIX ASPHALT (TYPE A), IMPORTED BORROW, AND ROADWAY EXCAVATION. |
Location Description | MONO COUNTY ABOUT 6 MILES NORTH OF LEE VINING FROM ROUTE 167 TO 0.4 MILE NORTH OF CONWAY RANCH ROAD |
QA Service Level | 1 (Verified on 07/31/2023) |
Sample Information
Sample Taken Date | 10/17/2023 | Sample Unique Key | 26 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/18/2023 |
Sample type | Quality Assurance | A brief description of the sample | 5000 Psi Mix / Mammoth |
The quantity of what the sample constitutes | 13 Cubic Yards / Mammoth Ready Mix | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Jeffery | Last name of sampler or witnessed by | Puente |
Title of sampler | QA | Telephone number of sampler | 6614400636 |
Laboratory sample identification | Conc-04 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Mammoth Ready Mix | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | 1304.18.25.A |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 58900 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | DS-1 Headwall Inlet | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-10-17-26
DIME Test ID: 2023-10-17-26-1
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: ASTM C39-21: Standard Test Method for Compressive Strength of Cylindrical Concrete Specimens
Test Release Date: 2023-10-23
Test Results
Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Derek Carrington
Date of test: 10/23/2023
Apparent mass of submerged cylinder 1: 3.5 lb
Average diameter of cylinder 1: 4.00 in
Average diameter of cylinder 2: 4.00 in
Average diameter of cylinder 3: 4.00 in
Maximum load on cylinder 1: 43390 lb
Maximum load on cylinder 2: 44900 lb
Maximum load on cylinder 3: 44750 lb
Type of fracture pattern of cylinder 1: 1
Type of fracture pattern of cylinder 2: 1
Type of fracture pattern of cylinder 3: 1
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Correction factor for cylinder 3: 1.00
Age of specimen: 6 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.57 in^2
Cross sectional area of cylinder 2: 12.57 in^2
Cross sectional area of cylinder 3: 12.57 in^2
Compressive strength of cylinder 1: 3450.0 psi
Compressive strength of cylinder 2: 3570.0 psi
Compressive strength of cylinder 3: 3560 psi
Compressive strength (to nearest 10 psi): 3530 psi
Serial number of delivery ticket, if available: no data
General comments (publicly viewable) (Max 1000 characters): DS-1 Headwall Inlet
Test was verified on 10/23/2023 ✔