Summary for Test 2023-10-02-66-2

Test performed: AASHTO T209-22

Project Information

Project IdentifiersProject ID: 209820
DEA: 04297634
EFIS: 0415000040
COOP: 042548
DIST-CO-RTE-PM04-ALA-84,680-17.9/21
Award Date02/19/2021
Closeout DateNot set
Work DescriptionROUTE 84 WIDENING (4-LANE EXPRESSWAY) FROM I-680 TO PIGEON PASS, INCLUDING INTERSECTION, DRAINAGE IMPROVEMENTS AND UTILITY RELOCATION.
Location DescriptionALAMEDA COUNTY IN AND NEAR SUNOL, PLEASANTON, AND LIVERMORE ON ROUTE 84 FROM 0.1 MILE EAST OF ROUTE 680 TO 0.1 MILE SOUTH OF RUBY HILL DRIVE AND ON ROUTE 680 FROM 1.2 MILES SOUTH TO 1.8 MILES NORTH OF ROUTE 84
QA Service Level1 (Verified on 11/04/2019)

Sample Information

Sample Taken Date10/02/2023 Sample Unique Key66
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/03/2023
Sample typeQuality Assurance A brief description of the sampleHot Mix Asphalt
The quantity of what the sample constitutes750 Tons From where was the sample collectedJob Site
First name of sampler or witnessed byMond Last name of sampler or witnessed byOsawaru
Title of samplerAssistant Resident Engineer Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Pleasanton Plant Transportation Laboratory (TL) NumberC968231
Inspector Lot Number from the Transportation Laboratory (TL) FormLot 10 Sublot 4 Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number10
Sublot number4 HMA Mix Number220304

Test Details

DIME Sample ID: 2023-10-02-66
DIME Test ID: 2023-10-02-66-2
Testing Lab: CT D04 - Pleasanton Field Laboratory
Test Method: AASHTO T209-22: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-10-20

Test Results


Number of Samples: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Robert Lohman
Date of test: 10/04/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water 1: 7337.4 grams
Mass of oven-dry sample in air for Sample 1: 2568.3 grams
Mass of container filled with the sample and water for Sample 1: 8878.1 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.499
Theoretical maximum density at 25°C (77°F): 2492 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Lot 10 Sublot 4

Test was verified on 10/20/2023