Summary for Test 2023-10-03-63-4
Test performed: AASHTO T51-22Project Information
Project Identifiers | Project ID: 995210 DEA: 010N4004 EFIS: 0124000017 |
---|---|
DIST-CO-RTE-PM | 01-DN-101-0/4 |
Award Date | 07/26/2023 |
Closeout Date | 12/21/2023 |
Work Description | Pavement Repair |
Location Description | Not set |
QA Service Level | 1 (Verified on 10/11/2023) |
Sample Information
Sample Taken Date | 10/03/2023 | Sample Unique Key | 63 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/10/2023 |
Sample type | Quality Assurance | A brief description of the sample | pg64-16 |
The quantity of what the sample constitutes | 1 0f 1 can | From where was the sample collected | Job Site |
First name of sampler or witnessed by | renick | Last name of sampler or witnessed by | l |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Albina Klamath Falls | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-16 |
---|---|---|---|
Modified | No | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | ||
Certified Asphalt Supplier | Albina Asphalt (Klamath Falls Plant) - Klamath Falls OR | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2023-10-03-63
DIME Test ID: 2023-10-03-63-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T51-22: Standard Method of Test for Ductility of Asphalt Materials (Asphalt Binder)
Test Release Date: 2023-10-19
Test Results
Is a normal test obtainable?: Yes
Number of replicates tested: One
Input Type: Measured
Tester's full name: Alonso Lopez-Sanchez
Date of test: 10/18/2023
Ductility of test #1 (D1): 150 cm
Ductility of sample: 150 cm
General comments (publicly viewable) (Max 1000 characters): DUCTILITY
Test was verified on 10/19/2023 ✔