Summary for Test 2023-09-25-33-6

Test performed: AASHTO T304-11

Project Information

Project IdentifiersProject ID: 215435
DEA: 081L9804
EFIS: 0821000048
DIST-CO-RTE-PM08-SBD-38-R11.3/26.5
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level1 (Verified on 06/24/2021)

Sample Information

Sample Taken Date09/25/2023 Sample Unique Key33
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/26/2023
Sample typeVerification A brief description of the sampleJMF 3/4" HMA- A R15 0.5% LAS
The quantity of what the sample constitutes4 Bags Of Aggregate, 1 Bag Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byMatich Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0494A-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMatich Plant Rialto Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0040
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Matich Plant Rialto
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design numberLHP-63D Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-09-25-33
DIME Test ID: 2023-09-25-33-6
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T304-11: Standard Method of Test for Uncompacted Void Content of Fine Aggregate (Fine of Crushed Particles)
Test Release Date: 2023-11-16

Test Results


What test method is performed?: Method A
Input Type: Calculated
Tester's full name: Satish Jain
Date of test: 10/01/2023
Bulk dry specific gravity: 2.639
Average uncompacted voids: 46.6 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/16/2023