Summary for Test 2023-10-12-45-2
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994299 DEA: 100Y7804 EFIS: 1016000025 |
---|---|
DIST-CO-RTE-PM | 10-MPA-140-25.3/51.8 |
Award Date | 04/04/2023 |
Closeout Date | Not set |
Work Description | COLD PLANE EXISTING PAVEMENT AND RESURFACE WITH HMA. |
Location Description | MARIPOSA COUNTY FROM WHITLOCK ROAD NEAR MIDPINES TO YOSEMITE NATIONAL PARK |
QA Service Level | 1 (Verified on 10/04/2022) |
Sample Information
Sample Taken Date | 10/12/2023 | Sample Unique Key | 45 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 10/13/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4 HMA |
The quantity of what the sample constitutes | 4 boxes | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Wesley | Last name of sampler or witnessed by | Gee |
Title of sampler | Lab Technician | Telephone number of sampler | |
Laboratory sample identification | 23-H-293 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Santa Fe Winton | Transportation Laboratory (TL) Number | 042309 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 3/4 inch | Lot number | 7 |
Sublot number | 12 | HMA Mix Number | 23J10 |
Test Details
DIME Sample ID: 2023-10-12-45
DIME Test ID: 2023-10-12-45-2
Testing Lab: CT D10 - District 10 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-10-18
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Hans Camenzind
Date of test: 10/18/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 2018.8 g
Mass Loss: 103.7 g
Correction Factor (Percent by mass of HMA Specimen): 0.11 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.05 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/18/2023 ✔