Summary for Test 2023-10-09-30-3

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 215240
DEA: 021H6804
EFIS: 0216000010
DIST-CO-RTE-PM02-TEH-5-39/41.9
Award Date02/13/2023
Closeout DateNot set
Work DescriptionSB Cottonwood Scales
Location DescriptionNot set
QA Service Level1 (Verified on 10/23/2020)

Sample Information

Sample Taken Date10/09/2023 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/09/2023
Sample typeProduction Start-Up A brief description of the sample16 boxes of Lime Treated 1/2-inch Type A HMA (eq. PG 64-28 M) with 25.0% RAP and virgin PG 58-34 M binder from Valero (Benicia, CA)
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byCindy Last name of sampler or witnessed byBryant
Title of samplerTET Telephone number of sampler
Laboratory sample identificationD79370 Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis - Northstate Asphalt (Redding, CA) Transportation Laboratory (TL) Number853406
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number

Test Details

DIME Sample ID: 2023-10-09-30
DIME Test ID: 2023-10-09-30-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-10-26

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 10/10/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3016.2 g
Mass of the specimen and specimen basket assembly prior to ignition: 4589.1 g
Mass of HMA Sample prior to ignition: 1572.9 g
Mass Loss: 101.1 g
Mass of aggregate remaining after ignition: 1471.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.75 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 5.49 %
General comments (publicly viewable) (Max 1000 characters): Pb=5.49%

Test was verified on 10/26/2023