Summary for Test 2017-03-15-4-4

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 208945
DEA: 07288604
EFIS: 0700021080
COOP: 074663
DIST-CO-RTE-PM07-LA-710-6.0-9.4
Award Date09/02/2011
Closeout DateNot set
Work DescriptionGerald Desmond Bridge Replacement - A Design Build project. IQA samples will be selected by Port/Caltrans representatives and sent to Translab for testing.
Location DescriptionPort of Long Beach (District 7)
QA Service Level1 (Verified on 06/03/2013)

Sample Information

Sample Taken Date03/15/2017 Sample Unique Key4
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing03/20/2017
Sample typeQuality Assurance A brief description of the sampleHRC 500/510
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byTanya Last name of sampler or witnessed byWyckoff
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameCMC Rebar, HRC Transportation Laboratory (TL) NumberC906182
Inspector Lot Number from the Transportation Laboratory (TL) FormNA Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC Rebar
Coupler ManufacturerHRC Intermediate Assembler or FabricatorUnknown
Rebar Size#8 Coupler Model500/510
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop DiameterUnknown Rebar Hoop FabricatorUnknown
Coupler Component Heat/Lot Number(s)A162885 Rebar Heat Number(s)4061609
Rebar Size 2 Not set Coupler Unique IDNot set

Test Details

DIME Sample ID: 2017-03-15-4
DIME Test ID: 2017-03-15-4-4
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile Slip)
Test Release Date: 2017-03-28

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Fred
Date of test: 03/20/2017
UTM: 400KIP
Halo ID: Small
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Slip (inch)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12208#8/25mm0.7907750098101OK NeckingFred

General comments (publicly viewable) (Max 1000 characters): OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 3/21/2017