Summary for Test 2023-10-09-27-5

Test performed: AASHTO T316-17

Project Information

Project IdentifiersProject ID: 994441
DEA: 081A8304
EFIS: 0800000579
COOP: 081746
DIST-CO-RTE-PM08---
Award Date10/05/2022
Closeout DateNot set
Work DescriptionWidening the existing Cedar Avenue overcrossing (OC) from 6 to 10 lanes, replacing the Union Pacific Railroad overhead (OH), widening Cedar Avenue from 4 to 6 through lanes, and realigning and/or widening the interchange entrance and exit ramps
Location DescriptionAt the Interstate 10 (I-10) Cedar Avenue Interchange from PM 17.8 to 19.3 in the County of San Bernardino (County)
QA Service Level2 (Verified on 12/13/2022)

Sample Information

Sample Taken Date10/09/2023 Sample Unique Key27
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/11/2023
Sample typeVerification A brief description of the sampleJMF Verification
The quantity of what the sample constitutes1 Can From where was the sample collectedSource
First name of sampler or witnessed byKee Ooi/Vicente Last name of sampler or witnessed byBunyi
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Corona Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-28 M
ModifiedYes Lot number
Sublot number Tank number
Time of sample HMA Supplier
Certified Asphalt SupplierSeventeen Twenty Oil Company - Corona CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2023-10-09-27
DIME Test ID: 2023-10-09-27-5
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T316-17: Standard Method of Test for Viscosity Determination of Asphalt Binder Using Rotational Viscometer
Test Release Date: 2023-11-04

Test Results


Is viscosity reading in cP/Pa-s?: Pa-s
Input Type: Calculated
Tester's full name: Sunday Agude
Date of test: 10/11/2023
Time of test: 9:20 HH:MM
Test Temperature: 135 C
Speed: 50 rpm
Spindle size: 21 in
Torque: 71.2 %
Viscosity reading #1 (A) : 0.722 Pa-s
Viscosity reading #2 (B) : 0.704 Pa-s
Viscosity reading #3 (C): 0.71 Pa-s
Average viscosity: 0.712 Pa-s
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/4/2023