Summary for Test 2023-10-03-14-1

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 77777
DEA: CHEM-STOCK
EFIS: CHEM-STOCK
DIST-CO-RTE-PM59---
Award DateNot set
Closeout DateNot set
Work DescriptionSpecial project for Chem Lab stock material. Object Code: 1025. J2 DEA: 912680.
Location DescriptionNot set
QA Service LevelNOT VERIFIED

Sample Information

Sample Taken Date10/03/2023 Sample Unique Key14
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing10/09/2023
Sample typeVerification A brief description of the sampleDouble End Stud Anchor Bolt
The quantity of what the sample constitutes48 From where was the sample collectedManufacturer
First name of sampler or witnessed byEDWARD Last name of sampler or witnessed byLEACH
Title of samplerQA Telephone number of sampler7072903887
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameA&M Bolt Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS38-056-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)3124384, 20837470, 122525-0 Nut Mfg. Lot Number(s)37462-20837470
Washer Mfg. Lot Number(s)E3308 Bolt SpecificationASTM F1554 GR. 55
Bolt Length(s)36 Nut SpecificationA194
Washer SpecificationF436 FinishHDG / MG
Diameter/Size1-1/4"-7 Bolt Mfg. Lot Number
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2023-10-03-14
DIME Test ID: 2023-10-03-14-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-10-12

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 10/10/2023
UTM: 400kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A171226Proof Load

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 10/12/2023