Summary for Test 2017-03-06-6-2
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 209141 DEA: 07215954 EFIS: 0700001835 |
---|---|
DIST-CO-RTE-PM | 07-LA-5-0.0/7.6 |
Award Date | 04/24/2014 |
Closeout Date | 07/14/2022 |
Work Description | WIDENING FREEWAY AND RECONSTRUCT OVERHEAD AND OVERCROSSING STRUCTURES |
Location Description | LOS ANGELES COUNTY IN LA MIRADA, SANTA FE SPRINGS, NORWALK AND DOWNEY FROM ORANGE COUNTY/LOS ANGELES COUNTY LIMIT LINES TO 0.7 MILE NORTH OF ROUTE 605 |
QA Service Level | 1 (Verified on 06/02/2014) |
Sample Information
Sample Taken Date | 03/06/2017 | Sample Unique Key | 6 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 03/10/2017 |
Sample type | Department Acceptance | A brief description of the sample | Flash Welded Rebar Hoops |
The quantity of what the sample constitutes | 8 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Tory | Last name of sampler or witnessed by | Mclaurin |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | Unknown | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | RKR Steel Welding | Transportation Laboratory (TL) Number | C940291 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | L6703917 | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Production Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 65025273 65025286 |
Hoop Manufacturer Lot Number(s) | 56 61 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | 6 |
Diameter of Hoop | 2.5'-0" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Gerdau |
Welding Company | RKR Steel Welding | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2017-03-06-6
DIME Test ID: 2017-03-06-6-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-03-20
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name: Arnold
Date of test: 03/13/2017
UTM: 400KIP
Temperature: 71 F
Num | Sample | Mfg. Lot Number(s) | Size | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|
1 | 2 | 56 | #6/19mm | 0.44 | 42480 | 96550 | Bar Broke | Arnold |
General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point FileTest graph for the Sample
Test was verified on 3/13/2017 ✔