Summary for Test 2016-03-28-2-1
Test performed: AGGLP SIEVE_ANALYSIS-1Project Information
Project Identifiers | Project ID: 211450 DEA: 033F3604 EFIS: 0312000216 |
---|---|
DIST-CO-RTE-PM | 03--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 10/19/2016) |
Sample Information
Sample Taken Date | 03/28/2016 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 02/23/2017 |
Sample type | Quality Control | A brief description of the sample | SOUTHSIDE PARK VIADUCT |
The quantity of what the sample constitutes | 1 BAG | From where was the sample collected | Job Site |
First name of sampler or witnessed by | FERNANDO | Last name of sampler or witnessed by | DE HARO |
Title of sampler | Unknown | Telephone number of sampler | Unknown |
Laboratory sample identification | 17SOIL-0029 | Linked DIME Sample ID | Unknown |
The fabricator/manufacturer/facility name | NA | Transportation Laboratory (TL) Number | C637023 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Unknown | Structure unique identifier | Not set |
Structure name | Not set |
Material Information
Material Type | Soil | The fabricator's/manufacturer's product name for the sample | Unknown |
---|---|---|---|
The fabricator/manufacturer designation for the sample | Unknown | A detailed description of where the material sample was collected | RC-16-001 |
Where the material sample would have been placed if not sampled | 88 TO 100 FT |
Test Details
DIME Sample ID: 2016-03-28-2
DIME Test ID: 2016-03-28-2-1
Testing Lab: CT HQ - Sacramento Aggregate Testing Laboratory
Test Method: AGGLP SIEVE_ANALYSIS-1: Soils for Corrosion Sieve Analysis
Test Release Date: 2017-03-09
Test Results
Input Type: Measured
Tester's full name: Phillip Montes
Date of test: 03/02/2017
Total mass of material in the sample: 1928 grams
Cumulative mass retained on the 2 in. sieve: 0 grams
Cumulative mass retained on the 1 1/2 in. sieve: 0 grams
Cumulative mass retained on the 1 in. sieve: 0 grams
Cumulative mass retained on the 3/4 in. sieve: 0 grams
Cumulative mass retained on the 1/2 in. sieve: 2 grams
Cumulative mass retained on the 3/8 in. sieve: 3 grams
Cumulative mass retained on the #4 sieve: 3 grams
Cumulative mass retained on the #8 sieve: 0 grams
Total sample mass passing the #4 sieve: 977 grams
Total mass of fine material in the sample: 483 grams
Cumulative mass retained on the pan: 483 grams
Total cumulative mass of coarse aggregate: 8 grams
Total cumulative mass of fine aggregate: 483 grams
Sum of coarse and fine aggregate: 985 grams
Percentage of coarse material: 1 %
Percentage of fine material: 99 %
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 100 %
Cumulative percent passing the 3/8 in. sieve: 99 %
Cumulative percent passing the #4 sieve: 99 %
Cumulative percent passing the #8 sieve: 99 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 3/2/2017 ✔