Summary for Test 2023-09-20-47-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 994431
DEA: 024J1604
EFIS: 0222000145
DIST-CO-RTE-PM02---
Award DateNot set
Closeout DateNot set
Work DescriptionNot set
Location DescriptionNot set
QA Service Level2 (Verified on 03/28/2023)

Sample Information

Sample Taken Date09/20/2023 Sample Unique Key47
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/20/2023
Sample typeProduction Start-Up A brief description of the sample16 boxes of Lime Treated 3/4-inch Type A HMA (eq. PG 64-16) with 23.0% RAP and virgin PG 58-22 from Albina (Klamath Falls, OR)
The quantity of what the sample constitutesProduction Start Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byDawn Last name of sampler or witnessed bySloaterman
Title of samplerTET Telephone number of sampler
Laboratory sample identificationD79354 Linked DIME Sample ID
The fabricator/manufacturer/facility nameHat Creek Construction and Materials – Ward Lake Plant (Litchfield, CA) Transportation Laboratory (TL) Number858049
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeType A HMA
HMA Grading3/4 inch Lot number
Sublot number HMA Mix Number

Test Details

DIME Sample ID: 2023-09-20-47
DIME Test ID: 2023-09-20-47-1
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-10-03

Test Results


What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 09/21/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3015.5 g
Mass of the specimen and specimen basket assembly prior to ignition: 5091.5 g
Mass of HMA Sample prior to ignition: 2076.0 g
Mass Loss: 145.2 g
Mass of aggregate remaining after ignition: 1930.8 g
Correction Factor (Percent by mass of HMA Specimen): 0.69 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.14 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 6.16 %
General comments (publicly viewable) (Max 1000 characters): Pb=6.16

Test was verified on 10/3/2023