Summary for Test 2023-09-20-44-3
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994431 DEA: 024J1604 EFIS: 0222000145 |
---|---|
DIST-CO-RTE-PM | 02--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 2 (Verified on 03/28/2023) |
Sample Information
Sample Taken Date | 09/20/2023 | Sample Unique Key | 44 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 09/20/2023 |
Sample type | Production Start-Up | A brief description of the sample | 2 bags of Fine RAP |
The quantity of what the sample constitutes | Production Start-Up Evaluation | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Dawn | Last name of sampler or witnessed by | Sloaterman |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | D79353B | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Hat Creek Construction and Materials – Ward Lake Plant (Litchfield, CA) | Transportation Laboratory (TL) Number | 858050 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Reclaimed Asphalt Pavement | RAP Source | Ward Lake Pit |
---|---|---|---|
Aggregate Size | 3/8-inch | Aggregate Source | |
RAP Stockpile | Stockpile Size (tons) | ||
Reclaimed Asphalt Pavement Mix Number |
Test Details
DIME Sample ID: 2023-09-20-44
DIME Test ID: 2023-09-20-44-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-10-03
Test Results
What temperature unit is used?: Celsius
Input Type: Measured
Tester's full name: Terry McCormick
Date of test: 09/25/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 3016.0 g
Mass of the specimen and specimen basket assembly prior to ignition: 4584.8 g
Mass of HMA Sample prior to ignition: 1568.8 g
Mass Loss: 111.3 g
Mass of aggregate remaining after ignition: 1457.5 g
Correction Factor (Percent by mass of HMA Specimen): 0.00 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.19 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 6.90 %
General comments (publicly viewable) (Max 1000 characters): Pbr(uncorrected)=6.90%
Test was verified on 10/3/2023 ✔