Summary for Test 2023-08-23-89-1

Test performed: CTM 202-November 2011

Project Information

Project IdentifiersProject ID: 214663
DEA: 081F7304
EFIS: 0815000034
DIST-CO-RTE-PM08-SBD-215-2.7
Award DateNot set
Closeout DateNot set
Work DescriptionREPLACE CONCRETE BRIDGE, PLACE CONCRETE PCPS GIRDERS AND HMA.
Location DescriptionSAN BERNARDINO COUNTY IN COLTON AT WASHINGTON STREET OVERCROSSING
QA Service Level1 (Verified on 02/24/2021)

Sample Information

Sample Taken Date08/23/2023 Sample Unique Key89
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/24/2023
Sample typeQuality Control A brief description of the sample1in, 3/8 in, WCS
The quantity of what the sample constitutes1 Bag From where was the sample collectedJob Site
First name of sampler or witnessed byJames Last name of sampler or witnessed byPerchlak
Title of samplerQC Field Technician Telephone number of sampler
Laboratory sample identificationMix 1610974 Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameJob site Transportation Laboratory (TL) NumberUnknown
Inspector Lot Number from the Transportation Laboratory (TL) FormUnknown Structure unique identifier00-0000
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0040
The fabricator's/manufacturer's product name for the sampleSet 1 The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design number1610974 Lot number1
Sublot number1 Aggregate Mix Number

Test Details

DIME Sample ID: 2023-08-23-89
DIME Test ID: 2023-08-23-89-1
Testing Lab: G3 Quality, Incorporated - Cerritos
Test Method: CTM 202-November 2011: Method of Test for Sieve Analysis of Fine and Coarse Aggregates
Test Release Date: 2023-09-22

Test Results


What size aggregate is being tested?: 1 in. x No. 4 - Coarse Aggregate
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
For Combined Gradation only, has the fine aggregate sample been reduced?: No
For Combined Gradation only, use #40 Sieve?: No
Input Type: Calculated
Tester's full name: Paul Salazar
Date of test: 08/24/2023
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 97 %
Cumulative percent passing the 3/4 in. sieve: 82 %
Cumulative percent passing the 1/2 in. sieve: 48 %
Cumulative percent passing the 3/8 in. sieve: 31 %
Cumulative percent passing the #4 sieve: 12 %
Cumulative percent passing the #8 sieve: 7 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 9/22/2023