Summary for Test 2023-08-29-1-1

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 215620
DEA: 01436404
EFIS: 0100000193
DIST-CO-RTE-PM01-DN-101-35.8/36.5
Award Date07/11/2022
Closeout DateNot set
Work DescriptionDr. Fine Bridge Replacement
Location DescriptionDR. FINE BRIDGE REPLACEMENT FROM LAKE EARL DR TO S FRED D. HAIGHT DR ON HWY 101 ACROSS SMITH RIVER.
QA Service Level1 (Verified on 03/26/2021)

Sample Information

Sample Taken Date08/29/2023 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/11/2023
Sample typeQuality Assurance A brief description of the sampleAB547A transom bolt
The quantity of what the sample constitutes112 From where was the sample collectedDistributor
First name of sampler or witnessed byPaul Last name of sampler or witnessed byFarinha
Title of samplerASI Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameAcrow bridge Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) FormS51-890-23 Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)10811050,8000017500, 124418 Nut Mfg. Lot Number(s)W000013562
Washer Mfg. Lot Number(s)0323-681 Bolt SpecificationA325
Bolt Length(s)4.5" Nut SpecificationA563
Washer SpecificationF436 FinishHDG
Diameter/Size1" Bolt Mfg. Lot NumberE897F1
Rocap Test Requirement(s) Lubricant Requirements(s)lubricated

Test Details

DIME Sample ID: 2023-08-29-1
DIME Test ID: 2023-08-29-1-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load with Wedge)
Test Release Date: 2023-09-22

Test Results


Number of Bolt Samples: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 09/20/2023
UTM: 450kip
Temperature: no data
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)Wedge Angle (deg)CommentsTested By
11AE897F11.000087291388.2910.00Wedge Tensileaauvinen

General comments (publicly viewable) (Max 1000 characters): Wedge Tensile
Test Graph
Source: Bluehill Data Point File

Test was verified on 9/22/2023