Summary for Test 2023-09-08-22-3

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 994454
DEA: 010M7304
EFIS: 0123000063
DIST-CO-RTE-PM01-HUM-211-77.2/78.59999999999999
Award Date12/21/2022
Closeout DateNot set
Work DescriptionFernbridge Earthquake Restoration (Bridge No. 04-0134)
Location DescriptionNot set
QA Service Level1 (Verified on 01/03/2023)

Sample Information

Sample Taken Date09/08/2023 Sample Unique Key22
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing09/11/2023
Sample typeQuality Assurance A brief description of the sampleBarsplice Zap Screwlok Coupler
The quantity of what the sample constitutes4 From where was the sample collectedJob Site
First name of sampler or witnessed byR Last name of sampler or witnessed byDuran
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameBARSPLICE Transportation Laboratory (TL) NumberC897051
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateUltimate Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCascade
Coupler ManufacturerBarSplice Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelBarsplice Griptwist coupler
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)A222815/C216089 Rebar Heat Number(s)253723
Rebar Size 2 Coupler Unique IDSS-17-03

Test Details

DIME Sample ID: 2023-09-08-22
DIME Test ID: 2023-09-08-22-3
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2023-09-14

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 09/12/2023
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
13No. 11/36mm101.5614931495714Ok Neckingrmacias

General comments (publicly viewable) (Max 1000 characters): Ok Necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 9/14/2023