Summary for Test 2017-02-08-9-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211371
DEA: 120H2434
EFIS: 1214000038
DIST-CO-RTE-PM12-LA,ORA-91-R20.6/R20.7,R0.0/R2.8
Award Date06/15/2016
Closeout Date08/27/2018
Work DescriptionINSTALL FIBER OPTIC CABLE & CCTVS
Location DescriptionORANGE AND LOS ANGELES COUNTIES IN LA PALMA, BUENA PARK AND CERRITOS FROM 0.1 MILE WEST OF LOS ANGELES COUNTY LINE TO STANTON AVENUE UNDERCROSSING
QA Service Level1 (Verified on 09/01/2016)

Sample Information

Sample Taken Date02/08/2017 Sample Unique Key9
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/15/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes4 From where was the sample collectedFabricator
First name of sampler or witnessed byWilliam Last name of sampler or witnessed byClifford
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameUnknown Transportation Laboratory (TL) NumberC953748
Inspector Lot Number from the Transportation Laboratory (TL) FormL7800417 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateService Rebar Heat Number(s)PL16108469
Hoop Manufacturer Lot Number(s)1 Material Standard CodeASTM A706
Material Grade60 Rebar Size5
Diameter of Hoop3'-2" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerMartinez Steel
Welding CompanyMartinez Steel Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-02-08-9
DIME Test ID: 2017-02-08-9-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-02-22

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 02/15/2017
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
121#5/16mm0.3134510111320Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 2/15/2017