Summary for Test 2023-06-23-77-2
Test performed: AASHTO T275-07r12Project Information
Project Identifiers | Project ID: 994243 DEA: 044J8404 EFIS: 0416000027 |
---|---|
DIST-CO-RTE-PM | 04-CC-24-R3.4/R3.6 |
Award Date | 11/28/2022 |
Closeout Date | 11/27/2024 |
Work Description | SEISMIC RESTORATION. |
Location Description | CONTRA COSTA COUNTY IN ORINDA FROM 0.1 MILE WEST OF SAINT STEPHENS DRIVE OVERCROSSING TO 0.1 MILE EAST OF SAINT STEPHENS DRIVE OVERCROSSING. |
QA Service Level | 1 (Verified on 09/13/2022) |
Sample Information
Sample Taken Date | 06/23/2023 | Sample Unique Key | 77 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/28/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1/2-INCH HMA Types A and B W/25%RAP CORES |
The quantity of what the sample constitutes | LOT 1 SUBLOT 2 | From where was the sample collected | Source |
First name of sampler or witnessed by | Nick | Last name of sampler or witnessed by | Hall |
Title of sampler | Telephone number of sampler | 7072999133 | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | De Silva Gates Drier Drum | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | 1 |
Sublot number | 2 | HMA Mix Number | 6741 WM |
Test Details
DIME Sample ID: 2023-06-23-77
DIME Test ID: 2023-06-23-77-2
Testing Lab: CT D04 - Concord Field Laboratory
Test Method: AASHTO T275-07r12: Standard Method of Test for Bulk Specific Gravity (Gmb) of Compacted Asphalt Mixtures Using Paraffin-Coated Specimens (Bulk Specific Gravity)
Test Release Date: 2023-09-11
Test Results
Number of tests: 2
What test procedure is performed?: Method A
Input Type: Calculated
Tester's full name: IGNACIO ARECHIGA
Date of test: 07/06/2023
Bulk Specific Gravity: 2.246
Bulk Specific Gravity 2: 2.4
Average Bulk Specific Gravity: 2.323
General comments (publicly viewable) (Max 1000 characters): LOT 1 SUBLOT 2
De Silva Gates Drier Drum W/25%RAP
1 specimen failed.
Test was verified on 9/11/2023 ✔