Summary for Test 2023-08-25-13-4
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 993647 DEA: 081K0504 EFIS: 0818000173 |
---|---|
DIST-CO-RTE-PM | 08-RIV,SBD-62-84.9/90.2,90.2/94.0 |
Award Date | 05/27/2022 |
Closeout Date | 12/22/2023 |
Work Description | RHMA-G, PARTIAL DEPTH RECYCLING AND RECYCLING AGENT. |
Location Description | RIVERSIDE AND SAN BERNADINO COUNTIES NEAR VIDAL JUNCTION FROM ROUTE 177 TO 1.7 MILES EAST OF IRON MOUNTAIN PUMPING PLANT ROAD |
QA Service Level | 1 (Verified on 06/26/2023) |
Sample Information
Sample Taken Date | 08/25/2023 | Sample Unique Key | 13 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/17/2023 |
Sample type | Department Acceptance | A brief description of the sample | 1/2" RHMA-G 0.3% EVO |
The quantity of what the sample constitutes | 40 BOXES OF HMA | From where was the sample collected | Manufacturer |
First name of sampler or witnessed by | Hector QC | Last name of sampler or witnessed by | QC |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 0419G-23 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | Martin-Murrieta Coachella | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | RHMA-G |
---|---|---|---|
HMA Grading | 1/2 inch | Lot number | |
Sublot number | HMA Mix Number | 41218080 |
Test Details
DIME Sample ID: 2023-08-25-13
DIME Test ID: 2023-08-25-13-4
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-09-08
Test Results
What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Dylan Nault
Date of test: 08/18/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1623.9 g
Mass Loss: 117.3 g
Correction Factor (Percent by mass of HMA Specimen): -0.08 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 738 C
Corrected Asphalt Binder Content: 7.17 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 9/8/2023 ✔