Summary for Test 2023-07-12-35-7
Test performed: AASHTO T85-13Project Information
Project Identifiers | Project ID: 993529 DEA: 11430514 EFIS: 1119000008 |
---|---|
DIST-CO-RTE-PM | 11-SD-15-R31.3/R37.1 |
Award Date | 05/27/2022 |
Closeout Date | Not set |
Work Description | CRCP, FIBER OPTIC CABLE, AND HMA. |
Location Description | SAN DIEGO COUNTY IN AND NEAR ESCONDIDO FROM 0.2 MILE SOUTH OF ROUTE 15/78 SEPARATION TO 0.5 MILE NORTH OF DEER SPRINGS ROAD OVERCROSSING |
QA Service Level | 1 (Verified on 02/07/2022) |
Sample Information
Sample Taken Date | 07/12/2023 | Sample Unique Key | 35 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/17/2023 |
Sample type | Quality Assurance | A brief description of the sample | 3/4" HMA-A |
The quantity of what the sample constitutes | 14 boxes 3 bags | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Ben | Last name of sampler or witnessed by | Smith |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 6624-PSU | Linked DIME Sample ID | 2023-07-12-34 |
The fabricator/manufacturer/facility name | Martin Marietta | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Aggregate | Source Identification (SMARA, name of Pit or Job Site) | N/A |
---|---|---|---|
The fabricator's/manufacturer's product name for the sample | The fabricator/manufacturer designation for the sample | ||
The plant number | A detailed description of where the material sample was collected | Plant | |
Where the material sample would have been placed if not sampled | Primary Aggregate Nominal Size | 3/4 inch | |
The concrete mix design number | Lot number | ||
Sublot number | Aggregate Mix Number |
Test Details
DIME Sample ID: 2023-07-12-35
DIME Test ID: 2023-07-12-35-7
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T85-13: Standard Method of Test for Specific Gravity and Absorption of Coarse Aggregate (Coarse Specific Gravity)
Test Release Date: 2023-10-05
Test Results
Basis for relative density testing: Bulk
Input Type: Measured
Tester's full name: Daniel Smith
Date of test: 07/21/2023
Mass of sample saturated surface dry aggregate: 3114.2 grams
Mass of sample in water: 1925.5 grams
Mass of sample after oven drying: 3081.5 grams
Specific Gravity: 2.592
Absorption: 1.1 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 10/5/2023 ✔