Summary for Test 2017-02-08-2-1

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 211260
DEA: 072159U4
EFIS: 0715000160
DIST-CO-RTE-PM07-LA,ORA-5-0.0/1.5, 44.3/44.4
Award Date05/27/2016
Closeout Date08/01/2023
Work DescriptionCONSTRUCT HOV LANES AND MIX FLOW LANES.
Location DescriptionLOS ANGELES AND ORANGE COUNTIES IN BUENA PARK, LA MIRADA, CERRITOS AND SANTA FE SPRINGS FROM ARTESIA BOULEVARD UNDERCROSSING TO NORTH FORK COYOTE CREEK
QA Service Level1 (Verified on 03/16/2016)

Sample Information

Sample Taken Date02/08/2017 Sample Unique Key2
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing02/10/2017
Sample typeQuality Assurance A brief description of the sampleFlash Welded Rebar Hoops
The quantity of what the sample constitutes8 From where was the sample collectedFabricator
First name of sampler or witnessed byWilliam Last name of sampler or witnessed byClifford
Title of samplerUnknown Telephone number of samplerUnknown
Laboratory sample identificationUnknown Linked DIME Sample IDUnknown
The fabricator/manufacturer/facility nameRKR Steel Welding Transportation Laboratory (TL) NumberC953026
Inspector Lot Number from the Transportation Laboratory (TL) FormL7800517 Structure unique identifierNot set
Structure nameNot set

Material Information

Material TypeSMTL TM5 - Welded Hoops Production or Authorization TestingAuthorization Testing
Service or UltimateUltimate Rebar Heat Number(s)PL16201214
Hoop Manufacturer Lot Number(s)1, 3 Material Standard CodeASTM A706
Material Grade60 Rebar Size7
Diameter of Hoop4'-8" Epoxy CoatedNo
Epoxy Coating ColorNA Rebar ManufacturerRKR
Welding CompanyRKR Steel Welding Coating StandardsUncoated
Weld TypeFlash Welded

Test Details

DIME Sample ID: 2017-02-08-2
DIME Test ID: 2017-02-08-2-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Tensile)
Test Release Date: 2017-02-21

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name: Brian
Date of test: 02/13/2017
UTM: 400KIP
Temperature: 72 F
NumSampleMfg. Lot Number(s)SizeArea (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
111#7/22mm0.65634093900Bar BrokeBrian

General comments (publicly viewable) (Max 1000 characters): Bar Broke; OK Necking
Test Graph
Source: Partner Data Point File
Test graph for the Sample

Test was verified on 2/14/2017