Summary for Test 2023-07-13-2-6
Test performed: CTM 670-December 2013Project Information
Project Identifiers | Project ID: 88888 DEA: SMTL-STOCK EFIS: SMTL-STOCK |
---|---|
DIST-CO-RTE-PM | 59--- |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Special project for SMTL stock material. Object Code: 1025. J2 DEA: 912680. |
Location Description | Not set |
QA Service Level | NOT VERIFIED |
Sample Information
Sample Taken Date | 07/13/2023 | Sample Unique Key | 2 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | No | Date that the sample was received by the laboratory/organization performing the testing | 08/28/2023 |
Sample type | Verification | A brief description of the sample | Machine Qualification H&H S#H6182 |
The quantity of what the sample constitutes | 15 | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Sherri | Last name of sampler or witnessed by | Brannon |
Title of sampler | CALTRANS METS QA INSPECTOR | Telephone number of sampler | 9168266371 |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Conco Reinforcing Benicia | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B22-208-23 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM5 - Welded Hoops | Production or Authorization Testing | Authorization Testing |
---|---|---|---|
Service or Ultimate | Ultimate | Rebar Heat Number(s) | 3500032029 |
Hoop Manufacturer Lot Number(s) | 1 | Material Standard Code | ASTM A706 |
Material Grade | 60 | Rebar Size | #7 |
Diameter of Hoop | 5'-6" | Epoxy Coated | No |
Epoxy Coating Color | NA | Rebar Manufacturer | Nucor |
Welding Company | Conco Companies Benicia | Coating Standards | Uncoated |
Weld Type | Flash Welded |
Test Details
DIME Sample ID: 2023-07-13-2
DIME Test ID: 2023-07-13-2-6
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical)
Test Release Date: 2023-12-29
Test Results
Number of Samples Tested: 1
Input Type: Measured
Tester's full name: rmacias
Date of test: 08/29/2023
UTM: 400kip
Temperature: 72.00 f
Num | Sample | Number of Cycles | Size | Mfg. Lot Number(s) | Area (sqin) | Peak Load (lbf) | Peak Stress (psi) | Comments | Tested By |
---|---|---|---|---|---|---|---|---|---|
1 | 6 | No. 7/22mm | 1 | 0.6 | 56785 | 94641 | Break 1 Ok necking | rmacias |
General comments (publicly viewable) (Max 1000 characters): Break 1 Ok necking
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.
Test was verified on 12/29/2023 ✔