Summary for Test 2023-08-11-40-4

Test performed: AASHTO T313-22

Project Information

Project IdentifiersProject ID: 215744
DEA: 033H93U4
EFIS: 0321000091
DIST-CO-RTE-PM03-YUB,BUT-70-25.5/25.8,0.0/3.8
Award Date07/15/2021
Closeout DateNot set
Work DescriptionWIDEN ROADWAY & SHOULDER, ADD TURN LANES & CONSTRUCT BRIDGE.
Location DescriptionYUBA AND BUTTE COUNTIES ABOUT 11 MILES NORTH OF MARYSVILLE FROM 0.8 MILE NORTH OF CHANDLER ROAD TO 0.2 MILE SOUTH OF EAST GRIDLEY ROAD
QA Service Level1 (Verified on 05/20/2021)

Sample Information

Sample Taken Date08/11/2023 Sample Unique Key40
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/16/2023
Sample typeDepartment Acceptance A brief description of the samplePG 64-16 Valero
The quantity of what the sample constitutes1 Can From where was the sample collectedJob Site
First name of sampler or witnessed byTony Last name of sampler or witnessed byGranados
Title of samplerplants qc Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameTeichert Hallwood Transportation Laboratory (TL) Number803116
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAsphalt Binder Performance GradePG 64-16
ModifiedNo Lot number
Sublot number13 Tank number
Time of sample HMA SupplierTeichert Hollwood
Certified Asphalt SupplierValero Marketing & Supply - Benicia CA MultigradeNo
Multigrade Type Asphalt Binder Mix Number

Test Details

DIME Sample ID: 2023-08-11-40
DIME Test ID: 2023-08-11-40-4
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T313-22: Standard Method of Test for Determining the Flexural Creep Stiffness of Asphalt Binder Using the Bending Beam Rheometer (BBR)
Test Release Date: 2023-08-29

Test Results


Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 08/29/2023
Minimum test bath temperature at 240 s: -6.0 C
Maximum test bath temperature at 240 s: -6.0 C
Time of test load application: no data
File name of test data: no data
Time beam in bath: no data
Time test started: no data
Flags issued by software during test: no data
Correlation coefficient (R²): 0
Regression coefficient a: no data
Regression coefficient b: no data
Regression coefficient c: no data
Load at time 0.0: 0.0 mN
Deflection at time 0.0 s: 0.000 µm
Load at time 0.5 s: 0.0 mN
Deflection at time 0.5 s: 0.000 µm
Load at 60.0 s: 0.0 mN
Beam deflection 60.0 s: 0.000 µm
Measured Stiffness Modulus 60.0 s: 57.100 mPa
Estimated Stiffness Modulus 60.0 s: 57.000 mPa
Difference between stiffness moduli 60.0 s: no data
Estimated m-value 60.0 s: 0.399
General comments (publicly viewable) (Max 1000 characters): BBR

Test was verified on 8/29/2023