Summary for Test 2023-08-22-40-2

Test performed: CTM 670-December 2013

Project Information

Project IdentifiersProject ID: 993664
DEA: 073311U4
EFIS: 0719000098
DIST-CO-RTE-PM07-VEN-23,101-R3.3/R3.7,0.2/40.8
Award Date08/31/2022
Closeout DateNot set
Work DescriptionCONSTRUCT GUARDRAILS AND CONCRETE BARRIER.
Location DescriptionVENTURA COUNTY IN THOUSAND OAKS, CAMARILLO, OXNARD AND VENTURA ON ROUTE 101 FROM THE LOS ANGELES /VENTURA COUNTY LINE TO OLD PACIFIC COAST HIGHWAY AND ON ROUTE 23 FROM ROUTE 23/101 SEPARATION TO HILLCREST DRIVE
QA Service Level1 (Verified on 05/11/2022)

Sample Information

Sample Taken Date08/22/2023 Sample Unique Key40
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/28/2023
Sample typeQuality Assurance A brief description of the sample# 11 Lenton Couplers
The quantity of what the sample constitutes4 From where was the sample collectedManufacturer
First name of sampler or witnessed byNA Last name of sampler or witnessed byNA
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameCMC Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM5 - Couplers Production or Authorization TestingProduction Testing
Service or UltimateService Material Standard CodeASTM A706
Material Grade60 Rebar ManufacturerCMC
Coupler ManufacturerErico Intermediate Assembler or Fabricator
Rebar Size#11 Coupler ModelLenton A2
Coating StandardsUncoated Shape of RebarStraight
Rebar Hoop Diameter Rebar Hoop Fabricator
Coupler Component Heat/Lot Number(s)L9289 Rebar Heat Number(s)3120081
Rebar Size 2 Coupler Unique IDST-17-01

Test Details

DIME Sample ID: 2023-08-22-40
DIME Test ID: 2023-08-22-40-2
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: CTM 670-December 2013: Method of Tests for Mechanical and Welded Reinforcing Steel Splices (Cyclical/Fatique Tensile with Slip)
Test Release Date: 2023-08-29

Test Results


Number of Samples Tested: 1
Input Type: Measured
Tester's full name: aauvinen
Date of test: 08/28/2023
UTM: 400kip
Temperature: 72.00 f
Halo ID:
NumSampleNumber of CyclesSizeMfg. Lot Number(s)Slip (inch)Area (sqin)Peak Load (lbf)Peak Stress (psi)CommentsTested By
12No. 11/36mm101.5614094690350Service Spliceaauvinen

General comments (publicly viewable) (Max 1000 characters): Service Splice
Test Graph
Source: Bluehill Data Point File
WARNING: position or load not found in data points imported from Instron machine.

Test was verified on 8/29/2023