Summary for Test 2023-08-17-51-3
Test performed: CTM 521-June 2020Project Information
Project Identifiers | Project ID: 214336 DEA: 07302404 EFIS: 0713000488 |
---|---|
DIST-CO-RTE-PM | 07-VEN-101-37/40 |
Award Date | 11/17/2020 |
Closeout Date | 09/24/2024 |
Work Description | PADRE JUAN REHAB |
Location Description | VEN 101 |
QA Service Level | 1 (Verified on 02/26/2021) |
Sample Information
Sample Taken Date | 08/17/2023 | Sample Unique Key | 51 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/18/2023 |
Sample type | Quality Assurance | A brief description of the sample | 6x12 LCB cylinders |
The quantity of what the sample constitutes | 10 Cy | From where was the sample collected | Job Site |
First name of sampler or witnessed by | Aleksey | Last name of sampler or witnessed by | Souglobov |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | 23-1232 | Linked DIME Sample ID | |
The fabricator/manufacturer/facility name | N/A | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Concrete | The concrete mix design number | G3-22-LRCYB-297R |
---|---|---|---|
The truck number from where the sample was collected | The batch plant ticket number from where the sample was collected | 79 | |
Concrete batch plant | The fabricator/manufacturer designation for the sample | ||
A detailed description of where the material sample was collected | wheelbarrow | Where the material sample would have been placed if not sampled | |
From Lot No. | Bag Lot No. |
Test Details
DIME Sample ID: 2023-08-17-51
DIME Test ID: 2023-08-17-51-3
Testing Lab: Alta Vista Solutions - Whittier
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-08-25
Test Results
Unit system used?: US Units
Number of specimens: 2
Test performed: With no density determined
Input Type: Measured
Tester's full name: Nathan Ogbasellasie
Date of test: 08/24/2023
Capped in accordance with?: ASTM C1231 - Unbonded Elastomeric Pad Cap
Average diameter of cylinder 1: 5.95 in
Average diameter of cylinder 2: 5.95 in
Maximum load on cylinder 1: 21047 lb
Maximum load on cylinder 2: 20017 lb
Type of fracture pattern of cylinder 1: 3
Type of fracture pattern of cylinder 2: 3
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1.00
Correction factor for cylinder 2: 1.00
Age of specimen: 7 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 27.81 in^2
Cross sectional area of cylinder 2: 27.81 in^2
Compressive strength of cylinder 1: 756.8 psi
Compressive strength of cylinder 2: 719.8 psi
Compressive strength (to nearest 10 psi): 740 psi
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/25/2023 ✔