Summary for Test 2023-07-06-36-11

Test performed: AASHTO T84-14

Project Information

Project IdentifiersProject ID: 993409
DEA: 07327604
EFIS: 0716000132
DIST-CO-RTE-PM07-LA-39-32.2/38.4
Award Date03/07/2022
Closeout DateNot set
Work DescriptionINSTALL GUARDRAILS AND CONSTRUCT RETAINING WALLS.
Location DescriptionLOS ANGELES COUNTY NEAR AZUSA AT VARIOUS LOCATIONS FROM 0.3 MILE SOUTH OF NORTH FORK SAN GABRIEL RIVER OVERCROSSING TO 0.3 MILE NORTH CRYSTAL LAKE ROAD
QA Service Level1 (Verified on 12/06/2021)

Sample Information

Sample Taken Date07/06/2023 Sample Unique Key36
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/13/2023
Sample typeVerification A brief description of the samplePSUE 3/4" HMA-A-SP R15 0.5% LAS
The quantity of what the sample constitutes4 Bags Of Agg., 2 Bags Of Rap From where was the sample collectedManufacturer
First name of sampler or witnessed byJons Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0363A-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameVulcan Materials-Irwindale Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0035
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Cut at Vulcan Materials-Irwindale
Where the material sample would have been placed if not sampledAsphalt Paving Primary Aggregate Nominal Size3/4 inch
The concrete mix design number220831A IRW LTR Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-07-06-36
DIME Test ID: 2023-07-06-36-11
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T84-14: Standard Method of Test for Specific Gravity and Absorption of Fine Aggregate (Fine Specific Gravity)
Test Release Date: 2023-10-04

Test Results


Input Type: Measured
Tester's full name: Amir Behjati
Date of test: 07/15/2023
Mass of saturated surface dry sample (before pycnometer) (S): 500 grams
Mass of the pycnometer with water and aggregate (C): 973.2 grams
Mass of the pycnometer with water (B): 660.4 grams
Mass of the oven dried sample (before pycnometer) (A): 491 grams
Mass of the saturated surface dry aggregate (for absorption) (S): 500 grams
Mass of the oven dry aggregate (for absorption) (A): 491 grams
Test Sample Preparation: 6% Moisture
Bulk specific gravity: 2.623
Bulk specific gravity (SSD Basis): 2.671
Apparent specific gravity: 2.755
Absorption: 1.8 %
General comments (publicly viewable) (Max 1000 characters):