Summary for Test 2023-08-15-30-1

Test performed: AASHTO T308-10

Project Information

Project IdentifiersProject ID: 993647
DEA: 081K0504
EFIS: 0818000173
DIST-CO-RTE-PM08-RIV,SBD-62-84.9/90.2,90.2/94.0
Award Date05/27/2022
Closeout Date12/22/2023
Work DescriptionRHMA-G, PARTIAL DEPTH RECYCLING AND RECYCLING AGENT.
Location DescriptionRIVERSIDE AND SAN BERNADINO COUNTIES NEAR VIDAL JUNCTION FROM ROUTE 177 TO 1.7 MILES EAST OF IRON MOUNTAIN PUMPING PLANT ROAD
QA Service Level1 (Verified on 06/26/2023)

Sample Information

Sample Taken Date08/15/2023 Sample Unique Key30
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/17/2023
Sample typeDepartment Acceptance A brief description of the sample1/2" RHMA-G-SP 0.3% EVO
The quantity of what the sample constitutes3 BOXES OF RHMA From where was the sample collectedManufacturer
First name of sampler or witnessed byHector Last name of sampler or witnessed byQC
Title of sampler Telephone number of sampler
Laboratory sample identification0416G-23 Linked DIME Sample ID
The fabricator/manufacturer/facility nameMartin Marietta -Coachella Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeHot Mix Asphalt HMA TypeRHMA-G
HMA Grading1/2 inch Lot number
Sublot number HMA Mix Number41218080

Test Details

DIME Sample ID: 2023-08-15-30
DIME Test ID: 2023-08-15-30-1
Testing Lab: CT D08 - Fontana Southern Regional Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-08-23

Test Results


What temperature unit is used?: Celsius
Input Type: Calculated
Tester's full name: Antonio Torres
Date of test: 08/19/2023
Test procedure used?: Method A
Mass of HMA Sample prior to ignition: 1618.0 g
Mass Loss: 120.6 g
Correction Factor (Percent by mass of HMA Specimen): 0.06 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 C
Corrected Asphalt Binder Content: 7.28 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/23/2023