Summary for Test 2023-08-18-8-1
Test performed: ASTM F606-21Project Information
Project Identifiers | Project ID: 994506 DEA: 061F7204 EFIS: 0623000158 |
---|---|
DIST-CO-RTE-PM | 06-TUL-198-14.65, 14.65/14.65 |
Award Date | Not set |
Closeout Date | 11/16/2023 |
Work Description | Not set |
Location Description | Not set |
QA Service Level | 1 (Verified on 03/06/2023) |
Sample Information
Sample Taken Date | 08/18/2023 | Sample Unique Key | 8 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 08/21/2023 |
Sample type | Quality Assurance | A brief description of the sample | A325 HDG Bolt |
The quantity of what the sample constitutes | 1 lot of 120 bolts | From where was the sample collected | Fabricator |
First name of sampler or witnessed by | Ryan | Last name of sampler or witnessed by | Parr |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | XKT Engineering | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | B373-184-23 | Structure unique identifier | |
Structure name |
Material Information
Material Type | SMTL TM3 - Fastener Assembly | Rocap Number(s) | |
---|---|---|---|
Heat Number(s) | 1000218141, 1000112726, 226006 | Nut Mfg. Lot Number(s) | W000032927 |
Washer Mfg. Lot Number(s) | 226006 | Bolt Specification | ASTM A325 |
Bolt Length(s) | 2.5 | Nut Specification | ASTM A563 |
Washer Specification | ASTM F436 | Finish | HDG |
Diameter/Size | 7/8(9) | Bolt Mfg. Lot Number | W000036432 |
Rocap Test Requirement(s) | Lubricant Requirements(s) |
Test Details
DIME Sample ID: 2023-08-18-8
DIME Test ID: 2023-08-18-8-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-08-23
Test Results
Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 08/22/2023
UTM: 450kip
Temperature: 72 f
Num | Sample | Bolt Mfg. Lot Number | Size (in) | Peak Load (lbf) | Peak Load (kN) | Comments | Tested By |
---|---|---|---|---|---|---|---|
1 | 1A | 75868 | Proof Load |
General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.
Test was verified on 8/23/2023 ✔