Summary for Test 2023-08-11-1-1

Test performed: AASHTO T27-14

Project Information

Project IdentifiersProject ID: 994602
DEA: 09392004
EFIS: 0922000036
DIST-CO-RTE-PM09-INY-395-44.9/50.9,52.9/54.5
Award Date04/27/2023
Closeout Date12/22/2023
Work DescriptionHOT MIX ASPHALT (TYPE-A), SHOULDER BACKING, AND STRIPING.
Location DescriptionINYO COUNTY NEAR LONE PINE FROM 1.3 MILES SOUTH OF COTTONWOOD ROAD TO 2 MILES NORTH OF BARTLETT ROAD AND FROM 0.3 MILE SOUTH OF LUBKEN CANYON ROAD TO 1.1 MILES SOUTH OF GOLF COURSE ROAD
QA Service Level1 (Verified on 08/02/2023)

Sample Information

Sample Taken Date08/11/2023 Sample Unique Key1
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/14/2023
Sample typeDepartment Acceptance A brief description of the sample1/2" Agg. for use in HMA Type A
The quantity of what the sample constitutes1 bag From where was the sample collectedManufacturer
First name of sampler or witnessed byFred Last name of sampler or witnessed byHartman
Title of sampler Telephone number of sampler7609203898
Laboratory sample identificationCF 32, RAP 32 Linked DIME Sample ID
The fabricator/manufacturer/facility nameSully-Miller Blue Diamond Plant Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-36-0022
The fabricator's/manufacturer's product name for the sample The fabricator/manufacturer designation for the sample
The plant number A detailed description of where the material sample was collectedBelt Sampling Device at Plant
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1/2 inch
The concrete mix design number Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-08-11-1
DIME Test ID: 2023-08-11-1-1
Testing Lab: CT D09 - Bishop Field Laboratory
Test Method: AASHTO T27-14: Standard Method of Test for Sieve Analysis of Fine and Coarse Aggregates (Sieve Analysis)
Test Release Date: 2023-08-17

Test Results


What type of gradation is being tested?: Combined Gradation
Individual or cumulative mass retained on each sieve?: Cumulative Mass Retained
Does this test use 1/4 sieve? (question for HMA Gradation Type): No
Has the fine aggregate sample been reduced?: Yes
Input Type: Calculated
Tester's full name: Derek Carrington
Date of test: 08/17/2023
Cumulative percent passing the 2 in. sieve: 100 %
Cumulative percent passing the 1 1/2 in. sieve: 100 %
Cumulative percent passing the 1 in. sieve: 100 %
Cumulative percent passing the 3/4 in. sieve: 100 %
Cumulative percent passing the 1/2 in. sieve: 97 %
Cumulative percent passing the 3/8 in. sieve: 84 %
Cumulative percent passing the #4 sieve: 64 %
Cumulative percent passing the #8 sieve: 52 %
Cumulative percent passing the #16 sieve: 39 %
Cumulative percent passing the #30 sieve: 27 %
Cumulative percent passing the #50 sieve: 15 %
Cumulative percent passing the #100 sieve: 7 %
Cumulative percent passing the #200 sieve: 4.3 %
General comments (publicly viewable) (Max 1000 characters): CF-32

Test was verified on 8/17/2023