Summary for Test 2023-07-20-42-2

Test performed: CTM 521-June 2020

Project Information

Project IdentifiersProject ID: 212720
DEA: 07291404
EFIS: 0712000094
DIST-CO-RTE-PM07-LA-1-55-58
Award Date02/18/2021
Closeout DateNot set
Work DescriptionTRANCAS CREEK BRIDGE REPLACEMENT
Location DescriptionIN LOS ANGELES IN CITY OF MALIBU AT TRANCAS CREEK BRIDGE (53-0027).
QA Service Level1 (Verified on 04/02/2021)

Sample Information

Sample Taken Date07/20/2023 Sample Unique Key42
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/24/2023
Sample typeDepartment Acceptance A brief description of the sample4X8 PCC cylinders
The quantity of what the sample constitutes130 CY From where was the sample collectedJob Site
First name of sampler or witnessed byHamid Last name of sampler or witnessed byBoroomand
Title of samplerAssistant Structure Representative Telephone number of sampler
Laboratory sample identification23-282 Linked DIME Sample ID
The fabricator/manufacturer/facility nameAssociated Ready Mix Transportation Laboratory (TL) Number072023
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeConcrete The concrete mix design numberSL675350sp
The truck number from where the sample was collected0720 The batch plant ticket number from where the sample was collected6125500
Concrete batch plantAssociated Ready Mix The fabricator/manufacturer designation for the sample
A detailed description of where the material sample was collectedtruck chute Where the material sample would have been placed if not sampled
From Lot No. Bag Lot No.

Test Details

DIME Sample ID: 2023-07-20-42
DIME Test ID: 2023-07-20-42-2
Testing Lab: CT D07 - Materials Field Laboratory, Unit 1953
Test Method: CTM 521-June 2020: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2023-08-17

Test Results


Unit system used?: US Units
Number of specimens: 3
Test performed: With no density determined
Input Type: Measured
Tester's full name: Arnold Truong
Date of test: 08/17/2023
Capped in accordance with?: ASTM C617 - Sulfur Mortar Cap
Average diameter of cylinder 1: 4.03 in
Average diameter of cylinder 2: 4.03 in
Average diameter of cylinder 3: 4.02 in
Maximum load on cylinder 1: 73769 lb
Maximum load on cylinder 2: 73028 lb
Maximum load on cylinder 3: 75124 lb
Type of fracture pattern of cylinder 1: 2
Type of fracture pattern of cylinder 2: 2
Type of fracture pattern of cylinder 3: 2
Comment on any defect in either specimen or caps (Max 250 Characters): no data
Correction factor for cylinder 1: 1
Correction factor for cylinder 2: 1
Correction factor for cylinder 3: 1
Age of specimen: 28 days
Age of specimen in hours: 0 hours
Cross sectional area of cylinder 1: 12.76 in^2
Cross sectional area of cylinder 2: 12.76 in^2
Cross sectional area of cylinder 3: 12.69 in^2
Compressive strength of cylinder 1: 5781.3 psi
Compressive strength of cylinder 2: 5723.2 psi
Compressive strength of cylinder 3: 5919.9 psi
Compressive strength (to nearest 10 psi): 5810 psi
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 8/17/2023