Summary for Test 2023-06-15-52-1
Test performed: AASHTO T308-10Project Information
Project Identifiers | Project ID: 994436 DEA: 11080284 EFIS: 1117000085 |
---|---|
DIST-CO-RTE-PM | 11-IMP-98-32.1/32.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Place HMA, minor concrete, modify drainage, landscape and electrical. |
Location Description | IMPERIAL COUNTY IN CALEXICO FROM OLLIE AVENUE TO 0.1 MILE EAST OF ROCKWOOD AVENUE |
QA Service Level | 1 (Verified on 12/09/2022) |
Sample Information
Sample Taken Date | 06/15/2023 | Sample Unique Key | 52 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/16/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1-1/2" HMA |
The quantity of what the sample constitutes | 8 boxes 5 bags | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Loper |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | API Gateway | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | Not Applicable | Lot number | |
Sublot number | HMA Mix Number | 16 |
Test Details
DIME Sample ID: 2023-06-15-52
DIME Test ID: 2023-06-15-52-1
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: AASHTO T308-10: Standard Method of Test for Determining the Asphalt Binder Content of Hot Mix Asphalt (HMA) by the Ignition Method (Method A) (Asphalt Binder Content)
Test Release Date: 2023-08-11
Test Results
What temperature unit is used?: Fahrenheit
Input Type: Measured
Tester's full name: Melchor Oronoz
Date of test: 08/07/2023
Test procedure used?: Method A
Mass of the specimen basket assembly: 4010.1 g
Mass of the specimen and specimen basket assembly prior to ignition: 8058.9 g
Mass of HMA Sample prior to ignition: 4048.8 g
Mass Loss: 167.3 g
Mass of aggregate remaining after ignition: 3881.5 g
Correction Factor (Percent by mass of HMA Specimen): -0.16 %
Moisture Content: 0.00 %
Temperature Compensation Factor: 0.00 %
Test Temperature: 538 F
Corrected Asphalt Binder Content: 4.29 %
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/11/2023 ✔