Summary for Test 2023-08-02-28-1

Test performed: ASTM F606-21

Project Information

Project IdentifiersProject ID: 994090
DEA: 01434804
EFIS: 0100000672
DIST-CO-RTE-PM01-MEN-1-62.0/62.3
Award Date10/21/2022
Closeout DateNot set
Work DescriptionPudding Creek Bridge Widening
Location DescriptionMENDOCINO COUNTY IN FORT BRAGG FROM ELM STREET TO PUDDING CREEK ROAD 421
QA Service Level1 (Verified on 07/11/2022)

Sample Information

Sample Taken Date08/02/2023 Sample Unique Key28
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/02/2023
Sample typeQuality Assurance A brief description of the sampleFastener Assembly
The quantity of what the sample constitutes164 From where was the sample collectedJob Site
First name of sampler or witnessed byWill Last name of sampler or witnessed byCudney
Title of sampler Telephone number of sampler
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility namePortland Bolt Transportation Laboratory (TL) NumberC928679
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeSMTL TM3 - Fastener Assembly Rocap Number(s)
Heat Number(s)212485 8000015558 Nut Mfg. Lot Number(s)W000011953
Washer Mfg. Lot Number(s) Bolt SpecificationA449
Bolt Length(s)26 Nut SpecificationDH HVY HEX
Washer SpecificationNA FinishHDG
Diameter/Size7/8 Bolt Mfg. Lot Number212485
Rocap Test Requirement(s) Lubricant Requirements(s)

Test Details

DIME Sample ID: 2023-08-02-28
DIME Test ID: 2023-08-02-28-1
Testing Lab: CT HQ - Sacramento Structural Materials Testing Laboratory
Test Method: ASTM F606-21: Standard Test Methods for Determining the Mechanical Properties of Externally and Internally Threaded Fasteners, Washers, Direct Tension Indicators, and Rivets (Proof Load)
Test Release Date: 2023-08-11

Test Results


Number of Samples: 1
Input Type: Measured
Tester's full name:
Date of test: 08/10/2023
UTM: 450kip
Temperature: 72 f
NumSampleBolt Mfg. Lot NumberSize (in)Peak Load (lbf)Peak Load (kN)CommentsTested By
11A75360Proof Load

General comments (publicly viewable) (Max 1000 characters): Proof Load
Test Graph
Source: Bluehill Data Point File
WARNING: time or load not found in data points imported from Instron machine.

Test was verified on 8/11/2023