Summary for Test 2023-06-14-77-7
Test performed: CTM 389-19Project Information
Project Identifiers | Project ID: 994436 DEA: 11080284 EFIS: 1117000085 |
---|---|
DIST-CO-RTE-PM | 11-IMP-98-32.1/32.5 |
Award Date | Not set |
Closeout Date | Not set |
Work Description | Place HMA, minor concrete, modify drainage, landscape and electrical. |
Location Description | IMPERIAL COUNTY IN CALEXICO FROM OLLIE AVENUE TO 0.1 MILE EAST OF ROCKWOOD AVENUE |
QA Service Level | 1 (Verified on 12/09/2022) |
Sample Information
Sample Taken Date | 06/14/2023 | Sample Unique Key | 77 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 06/16/2023 |
Sample type | Quality Assurance | A brief description of the sample | 1-1/2" HMA |
The quantity of what the sample constitutes | 16 boxes 11 bags | From where was the sample collected | Supplier |
First name of sampler or witnessed by | Joe | Last name of sampler or witnessed by | Loper |
Title of sampler | Telephone number of sampler | ||
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | API Gateway | Transportation Laboratory (TL) Number | |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Hot Mix Asphalt | HMA Type | Type A HMA |
---|---|---|---|
HMA Grading | Not Applicable | Lot number | |
Sublot number | HMA Mix Number |
Test Details
DIME Sample ID: 2023-06-14-77
DIME Test ID: 2023-06-14-77-7
Testing Lab: CT D11 - District 11 Materials Laboratory
Test Method: CTM 389-19: Method of Test for Hamburg Wheel-Track Testing of Compacted Hot Mix Asphalt
Test Release Date: 2023-08-09
Test Results
Specified number of passes at 12.7 mm: 20000
Input Type: Measured
Tester's full name: Melchor Oronoz
Date of test: 07/27/2023
Test Temperature: 131 F
HMA Production: Field Plant Produced
Compaction Method: SGC Cylindrical Specimen
Type and Amount of Anti-Stripping Additive: 1.0%
Stripping Inflection Point (Wheel A): >20000
Stripping Inflection Point (Wheel B): >12500
Maximum impression at 5000 passes (left wheel): 1.15 mm
Maximum impression at 5000 passes (right wheel): 0.9 mm
Average impression at 5000 passes (left/right avg): 1.02 mm
Maximum impression at 10000 passes (left wheel): 1.4 mm
Maximum impression at 10000 passes (right wheel): 0.96 mm
Average impression at 10000 passes (left/right avg): 1.18 mm
Maximum impression at 15000 passes (left wheel): 1.53 mm
Maximum impression at 15000 passes (right wheel): 1.04 mm
Average impression at 15000 passes (left/right avg): 1.29 mm
Maximum impression at 20000 passes (left wheel): 1.58 mm
Maximum impression at 20000 passes (right wheel): 1.12 mm
Average impression at 20000 passes (left/right avg): 1.35 mm
Maximum impression at 25000 passes (left wheel): no data
Maximum impression at 25000 passes (right wheel): no data
Average impression at 25000 passes (left/right avg): no data
General comments (publicly viewable) (Max 1000 characters):
Test was verified on 8/9/2023 ✔