Summary for Test 2023-06-14-85-3

Test performed: AASHTO T209-12

Project Information

Project IdentifiersProject ID: 994345
DEA: 023J7804
EFIS: 0222000083
DIST-CO-RTE-PM02-TRI-36-15.8/16.9,20.5/24.5
Award Date12/22/2022
Closeout Date08/22/2023
Work DescriptionPLACE HOT MIX ASPHALT (TYPE A) AND REPLACE ASPHALT CONCRETE SURFACING.
Location DescriptionTRINITY COUNTY NEAR FOREST GLEN FROM 1.1 MILES WEST OF SOUTH FORK TRINITY RIVER BRIDGE TO SOUTH FORK TRINITY RIVER BRIDGE NO. 05-0026 AND FROM UPPER RATTLESNAKE CREEK BRIDGE NO. 05-0073 TO 0.3 MILE WEST OF TRINITY PINES ROAD
QA Service Level1 (Verified on 03/28/2023)

Sample Information

Sample Taken Date06/14/2023 Sample Unique Key85
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing06/14/2023
Sample typeProduction Start-Up A brief description of the sample2 bags of Fine RAP (3/8-inch)
The quantity of what the sample constitutesProduction Start-Up Evaluation From where was the sample collectedManufacturer
First name of sampler or witnessed byJD Last name of sampler or witnessed byAtkinson
Title of samplerTester Telephone number of sampler
Laboratory sample identificationD79264B Linked DIME Sample ID
The fabricator/manufacturer/facility nameTullis - Northstate Asphalt - Redding, CA Transportation Laboratory (TL) Number858118
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeReclaimed Asphalt Pavement RAP SourceTullis, Northstate Asphalt, Redding, CA
Aggregate Size3/8-inch Aggregate Source
RAP Stockpile Stockpile Size (tons)
Reclaimed Asphalt Pavement Mix Number

Test Details

DIME Sample ID: 2023-06-14-85
DIME Test ID: 2023-06-14-85-3
Testing Lab: CT D02 - Redding Northern Regional Laboratory
Test Method: AASHTO T209-12: Standard Method of Test for Theoretical Maximum Specific Gravity (Gmm) and Density of Asphalt Mixtures (Maximum Specific Gravity)
Test Release Date: 2023-08-03

Test Results


Number of tests: 1
What is the unit of measurement for theoretical density?: SI Units
Mass Determination: Air
Input Type: Measured
Tester's full name: Josh Murphy
Date of test: 06/15/2023
Method Performed: Mechanical Agitation - Method A
Mass of container filled with water: 7335.7 grams
Mass of oven-dry sample in air for Sample 1: 1578.1 grams
Mass of container filled with the sample and water for Sample 1: 8285.4 grams
Temperature of Water: 77 °F
Specific Gravity for Sample 1: 2.511
Theoretical maximum density at 25°C (77°F): 2503.7 kg/m^3
General comments (publicly viewable) (Max 1000 characters): Gmmr=2.511, Gser≈2.736

Test was verified on 8/3/2023