Summary for Test 2013-08-20-9308691-6

Test performed: CTM 521-June 2012

Project Information

Project IdentifiersProject ID: 7780
DEA: 112T1824
EFIS: 1100020051
DIST-CO-RTE-PM11-SD-805-4.7/5.6
Award Date01/03/2013
Closeout Date09/07/2018
Work DescriptionREPLACE STRUCTURE AND CONSTRUCT DIRECT ACCESS RAMP (DAR).
Location DescriptionSAN DIEGO COUNTY IN CHULA VISTA FROM 0.4 MILE SOUTH OF EAST PALOMAR STREET OVERCROSSING TO 0.1 MILE NORTH OF NAPLES STREET UNDERCROSSING
QA Service Level1 (Verified on 12/10/2012)

Sample Information

Sample Taken Date08/20/2013 Sample Unique Key9308691
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing08/21/2013
Sample typeQuality Control A brief description of the sampleSet 2
The quantity of what the sample constitutes4 cylinders From where was the sample collectedSource
First name of sampler or witnessed byHalden Last name of sampler or witnessed byGeorge
Title of samplerCWE Lab Tech Telephone number of sampler(925) 989-6385
Laboratory sample identification2013-08-20-0930 Linked DIME Sample IDNot set
The fabricator/manufacturer/facility nameVulcan Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier311RW
Structure nameSound Barrier Wall

Material Information

Material TypeConcrete The concrete mix design number103612F
The truck number from where the sample was collected394 The batch plant ticket number from where the sample was collected147811
Concrete batch plantNot set The fabricator/manufacturer designation for the sampleVulcan / 103612F
A detailed description of where the material sample was collectedSound Wall Where the material sample would have been placed if not sampledSound Wall
From Lot No.Not set Bag Lot No.Not set

Test Details

DIME Sample ID: 2013-08-20-9308691
DIME Test ID: 2013-08-20-9308691-6
Testing Lab: Vulcan Materials Company - San Diego
Test Method: CTM 521-June 2012: Method of Test for Compressive Strength of Molded Concrete Cylinders
Test Release Date: 2013-11-18

Test Results


Number of specimens:
Input Type: Calculated
Tester's full name: christian wheeler
Date of test: 10/15/2013
Correction factor: no data
Cylinder Age: 56 days
Break Description of Cylinder 1 (if not 'cone'): no data
Compressive Strength of Cylinder 1: 6690 lb/in^2
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 11/18/2013