Summary for Test 2023-07-20-43-7

Test performed: CTM 226-July 2010

Project Information

Project IdentifiersProject ID: 215314
DEA: 07333004
EFIS: 0716000298
DIST-CO-RTE-PM07-LA-5,5-15.1/22.9
Award Date10/20/2022
Closeout DateNot set
Work DescriptionPROJECT PILOT 1
Location DescriptionLOS ANGELES COUNTY IN AND NEAR LOS ANGELES ON ROUTE 5 FROM 0.1 MILE SOUTH OF CALZONA STREET TO 0.1 MILE SOUTH OF RIVERSIDE DRIVE AND ROUTE 2 AT LOS ANGELES REGIONAL TRANSPORTATION MANAGEMENT CENTER
QA Service Level1 (Verified on 07/12/2021)

Sample Information

Sample Taken Date07/20/2023 Sample Unique Key43
Will the laboratory/organization for which you are a member perform testing on this material sample?Yes Date that the sample was received by the laboratory/organization performing the testing07/27/2023
Sample typeAcceptance A brief description of the sample1x4 PCC Aggregates
The quantity of what the sample constitutes50 cy From where was the sample collectedManufacturer
First name of sampler or witnessed byvictor Last name of sampler or witnessed byPham
Title of sampler Telephone number of sampler2137924794
Laboratory sample identification Linked DIME Sample ID
The fabricator/manufacturer/facility nameNational Vernon Transportation Laboratory (TL) Number
Inspector Lot Number from the Transportation Laboratory (TL) Form Structure unique identifier
Structure name

Material Information

Material TypeAggregate Source Identification (SMARA, name of Pit or Job Site)91-19-0052
The fabricator's/manufacturer's product name for the sampleConcrete backfill The fabricator/manufacturer designation for the samplemix S63C653T1
The plant numberVernon A detailed description of where the material sample was collectedConveryor Belt
Where the material sample would have been placed if not sampled Primary Aggregate Nominal Size1 inch
The concrete mix design numberS63C653T1 Lot number
Sublot number Aggregate Mix Number

Test Details

DIME Sample ID: 2023-07-20-43
DIME Test ID: 2023-07-20-43-7
Testing Lab: CT D07 - Plant Services
Test Method: CTM 226-July 2010: Method of Test for Determination of Moisture Content of Soils and Aggregates by Oven Drying
Test Release Date: 2023-07-28

Test Results


Input Type: Measured
Tester's full name: Victor Pham
Date of test: 07/27/2023
Wet weight of the sample: 1145.0000000000 grams
Dry weight of the sample: 1089.0000000000 grams
Weight of water in sample: 56.0000000000 grams
Percent moisture: 5.1 %
General comments (publicly viewable) (Max 1000 characters):

Test was verified on 7/28/2023