Summary for Test 2023-07-12-48-1
Test performed: AASHTO T315-22Project Information
Project Identifiers | Project ID: 215741 DEA: 01366004 EFIS: 0100000127 |
---|---|
DIST-CO-RTE-PM | 01-HUM-101-80.0/84.0 |
Award Date | 12/29/2022 |
Closeout Date | Not set |
Work Description | Indianola Cutoff UC |
Location Description | HUMBOLDT COUNTY NEAR EUREKA FROM EUREKA SLOUGH BRIDGE TO BAYSIDE CUTOFF |
QA Service Level | 1 (Verified on 05/17/2021) |
Sample Information
Sample Taken Date | 07/12/2023 | Sample Unique Key | 48 |
---|---|---|---|
Will the laboratory/organization for which you are a member perform testing on this material sample? | Yes | Date that the sample was received by the laboratory/organization performing the testing | 07/21/2023 |
Sample type | Quality Assurance | A brief description of the sample | binder can |
The quantity of what the sample constitutes | 1 samples | From where was the sample collected | Source |
First name of sampler or witnessed by | Trena | Last name of sampler or witnessed by | Freitas |
Title of sampler | TET | Telephone number of sampler | |
Laboratory sample identification | Linked DIME Sample ID | ||
The fabricator/manufacturer/facility name | Valero Benicia | Transportation Laboratory (TL) Number | 972099 |
Inspector Lot Number from the Transportation Laboratory (TL) Form | Structure unique identifier | ||
Structure name |
Material Information
Material Type | Asphalt Binder | Performance Grade | PG 64-28 M |
---|---|---|---|
Modified | Yes | Lot number | |
Sublot number | Tank number | ||
Time of sample | HMA Supplier | Blue Lake Plant Kernen | |
Certified Asphalt Supplier | Valero Marketing & Supply - Benicia CA | Multigrade | No |
Multigrade Type | Asphalt Binder Mix Number |
Test Details
DIME Sample ID: 2023-07-12-48
DIME Test ID: 2023-07-12-48-1
Testing Lab: CT HQ - Sacramento Asphalt Binder Laboratory
Test Method: AASHTO T315-22: Standard Method of Test for Determining the Rheological Properties of Asphalt Binder Using a Dynamic Shear Rheometer (DSR) (Dynamic Shear)
Test Release Date: 2023-07-27
Test Results
Phase: Original binder
Input Type: Measured
Tester's full name: Raul Cardenas
Date of test: 07/26/2023
Test Gap: 1 mm
Test Frequency: 10.0 rad/s
Strain Amplitude: 12.00 %
Stress Amplitude: 0.503 kPa
Phase Angle (δ) (for the 10 cycles): 51.1 degree
Complex Modulus (G*) (for the 10 measurements): 4.167 kPa
Test Temperature (Specimen 1): 64.0 C
Dynamic Shear, G*/sin(δ): 5.35 kPa
General comments (publicly viewable) (Max 1000 characters): OG
Test was verified on 7/27/2023 ✔